Product Model
PST210-690-70T

Selling Points
- 1Advanced Motor Control: Efficiently manages motor start and stop with adjustable timing.
- 2Torque Control: Optimizes pump control with excellent start/stop characteristics.
- 3Robust Protection: Includes dual motor overload protection and adaptable underload protection.
- 4Fieldbus Communication: Supports Profibus, Modbus, Devicenet, or CANopen for seamless integration.
- 5Compact Design: Built-in by-pass contactor reduces wiring and installation time.
Technical Specifications
Detailed engineering parameters based on manufacturer documentation
Parameter | Value | Parameter | Value |
---|---|---|---|
Product Net Width | 360 mm | Product Net Height | 420 mm |
Product Net Depth / Length | 270 mm | Product Net Weight | 21.5 kg |
Rated Operational Voltage | Main Circuit 400 ... 690 V AC | Rated Control Supply Voltage (Us) | 100 ... 250 V AC |
Rated Control Circuit Voltage (Uc) | DC Operation 24 V | Rated Frequency (f) | 50/60 Hz Main Circuit 50 / 60 Hz |
Rated Operational Power - In-Line Connection (Pe) | (400 V) 110 kW (500 V) 132 kW (690 V) 184 kW | Rated Operational Current - In-Line Connection (Ie) | 210 A |
Rated Operational Power - Inside Delta Connection | at 400 V 184 kW at 500 V 250 kW at 690 V 315 kW | Rated Operational Current - Inside Delta Connection | 360 A |
Service Factor Percentage | 115 % | Overload Protection | Build-in electronic overload protection |
Integrated Electronic Overload | Yes | Adjustable Rated Motor Current Ie | 30 ... 115 % |
Starting Capacity at Maximum Rated Current Ie | 3xIe for 15s | Ramp Time | 0 ... 120 second [unit of time] 1 ... 120 second [unit of time] |
Initial Voltage During Start | 30 ... 70 % | Step Down Voltage Special Ramp | 100 ... 30 % |
Current Limit Function | 1.5 ... 7xIe | Switch for Inside Delta Connection | Yes |
Run Signal Relay | Yes | By-pass Signal Relay | Yes |
Fault Signal Relay | Yes | Overload Signal Relay | Yes |
Analog Outputs | 0â¦10 volts 0â¦20 mA 4â¦20 mA | Signal Indication Ready to Start/Standby ON (LED) | Green |
Signal Indication Protection (LED) | Yellow | Signal Indication Fault (LED) | Red |
Number of Starts Per Hour at 3.5*Ie for 7 sec. 50% ON Time 50% OFF Time | 30 | Communication | FiledBusPlug(Standard) |
Degree of Protection | acc. to IEC 60529, IEC 60947-1, EN 60529 Main Terminals IP00 | Terminal Type | Main Circuit: Bars |
Connecting Capacity Main Circuit | Hole Diameter 10.2 mm Width and Thickness 20x5 mm | Connecting Capacity Control Circuit | Rigid 1 x 2.5 mm² Rigid 2 x 1.5 mm² |
Connecting Capacity Supply Circuit | Rigid 1 x 2.5 mm² | Tightening Torque | Control Circuit 0.5 N·m Main Circuit 28 N·m Supply Circuit 0.5 N·m |
Product Main Type | PST210 | Ambient Air Temperature | Operation 0 ... +50 °C Storage -25 ... +70 °C |
Object Classification Code | Q | ETIM 7 | EC000640 - Soft starter |
ETIM 8 | EC000640 - Soft starter | ETIM 9 | EC000640 - Soft starter |
eClass | V11.0 : 27370907 | Manufacturer ID | 1SFA895012R7020 |
Specifications may be subject to change without notice