Product Model
T5H 630 PR222DS/P-LSIG In=630 4p F F

Selling Points
- 1Withstands 20,000 cycles at 120 cycles per hour, ensuring reliable performance in demanding environments.
- 2Constructed with solid-state release and thermal magnetic trip for enhanced safety and efficiency.
- 3Meets rigorous IEC standards for quality and performance, ensuring compatibility with various industrial systems.
- 4Supports up to 630 amps, making it suitable for heavy-duty applications.
- 5Measuring 186 mm in width, 103.5 mm in height, and 205 mm in depth, it fits seamlessly into modern control panels.
Technical Specifications
Detailed engineering parameters based on manufacturer documentation
Parameter | Value | Parameter | Value |
---|---|---|---|
Environmental Information | 9AKK10103A1056 9AKK108467A6707 | Product Net Width | 186 mm |
Product Net Height | 205 mm | Product Net Depth / Length | 103.5 mm |
Product Net Weight | 6.2 kg | Product Main Type | SACE Tmax T |
Product Name | Moulded Case Circuit Breaker | Product Type | Automatic Circuit Breaker |
Suitable For | T5 | Suitable for Product Class | Moulded Case Circuit Breakers |
Version | F | Electrical Durability | 5000 cycle 60 cycles per hour |
Mechanical Durability | 20000 cycle 120 cycles per hour | Number of Poles | 4 |
Power Loss | at Rated Operating Conditions per Pole 41 W | Rated Current (In) | 630 A |
Rated Impulse Withstand Voltage (Uimp) | 8 kV | Rated Insulation Voltage (Ui) | 1000 V |
Rated Operational Voltage | 690 V AC | Rated Service Short-Circuit Breaking Capacity (Ics) | (220 V AC) 100 kA (230 V AC) 100 kA (380 V AC) 70 kA (400 V AC) 70 kA (415 V AC) 70 kA (440 V AC) 65 kA (500 V AC) 50 kA (690 V AC) 40 kA |
Rated Ultimate Short-Circuit Breaking Capacity (Icu) | (220 V AC) 100 kA (230 V AC) 100 kA (380 V AC) 70 kA (400 V AC) 70 kA (415 V AC) 70 kA (440 V AC) 65 kA (500 V AC) 50 kA (690 V AC) 40 kA | Rated Uninterrupted Current (Iu) | 630 A |
Release | PR222DS/P-LSIG | Release Type | EL |
Short-Circuit Performance Level | H | Standards | IEC |
Sub-type | T5 | Terminal Connection Type | Fixed Circuit-Breakers Front |
Test Voltage Max (Utest) | 3500 V | Test Voltage at Industrial Frequency for 1 Minute | 3500 V |
ETIM 8 | EC000228 - Power circuit-breaker for trafo/generator/installation protection | ETIM 9 | EC000228 - Power circuit-breaker for trafo/generator/installation protection |
Object Classification Code | Q | UNSPSC | 39121100 |
WEEE Category | 5. Small Equipment (No External Dimension More Than 50 cm) | eClass | V11.1 : 27370409 |
Manufacturer ID | 1SDA054419R1 |
Specifications may be subject to change without notice