Product Model

T5L 400 PR222DS/P-LSI In=400 3p F F

In Stock
Last updated: 2025/4/19
ABB T5L 400 PR222DS/P-LSI In=400 3p F F

Selling Points

  • 1High Reliability: Designed for 20000 cycles at 120 cycles per hour, ensuring long-lasting performance.
  • 2Advanced Solid-State Release: Features a solid-state release mechanism for quick and precise circuit interruption.
  • 3Wide Voltage Compatibility: Operates at 220 V AC, 230 V AC, 380 V AC, 400 V AC, and more, making it versatile for different electrical systems.
  • 4High Short-Circuit Breaking Capacity: Capable of breaking 5 kA for 1 second, ensuring safe and efficient operation under short-circuit conditions.
  • 5Compliance with EU Directives: Meets EU Directive 2011/65/EU and Amendment 2015/863, ensuring environmental sustainability and safety standards.
Product Details
T5L 400 PR222DS/P-LSI In=400 3p F F
ABB

Technical Specifications

Detailed engineering parameters based on manufacturer documentation

ParameterValueParameterValue
Environmental Information
9AKK10103A1056 9AKK108467A6707
Product Net Width
140 mm
Product Net Height
205 mm
Product Net Depth / Length
103.5 mm
Product Net Weight
5.1 kg
Product Main Type
SACE Tmax T
Product Name
Moulded Case Circuit Breaker
Product Type
Automatic Circuit Breaker
Suitable For
T5
Suitable for Product Class
Moulded Case Circuit Breakers
Version
F
Electrical Durability
7000 cycle 60 cycles per hour
Mechanical Durability
20000 cycle 120 cycles per hour
Number of Poles
3
Power Loss
at Rated Operating Conditions per Pole 16.5 W
Rated Current (In)
400 A
Rated Impulse Withstand Voltage (Uimp)
8 kV
Rated Insulation Voltage (Ui)
1000 V
Rated Operational Voltage
690 V AC
Rated Service Short-Circuit Breaking Capacity (Ics)
(220 V AC) 200 kA (230 V AC) 200 kA (380 V AC) 120 kA (400 V AC) 120 kA (415 V AC) 120 kA (440 V AC) 100 kA (500 V AC) 85 kA (690 V AC) 70 kA
Rated Short-time Withstand Current Low Voltage (Icw)
for 1 s 5 kA
Rated Ultimate Short-Circuit Breaking Capacity (Icu)
(220 V AC) 200 kA (230 V AC) 200 kA (380 V AC) 120 kA (400 V AC) 120 kA (415 V AC) 120 kA (440 V AC) 100 kA (500 V AC) 85 kA (690 V AC) 70 kA
Rated Uninterrupted Current (Iu)
400 A
Release
PR222DS/P-LSI
Release Type
EL
Short-Circuit Performance Level
L
Standards
IEC
Sub-type
T5
Terminal Connection Type
Fixed Circuit-Breakers Front
Test Voltage Max (Utest)
3500 V
ETIM 8
EC000228 - Power circuit-breaker for trafo/generator/installation protection
ETIM 9
EC000228 - Power circuit-breaker for trafo/generator/installation protection
Object Classification Code
Q
UNSPSC
39121100
WEEE Category
5. Small Equipment (No External Dimension More Than 50 cm)
eClass
V11.1 : 27370409
Manufacturer ID
1SDA054369R1

Specifications may be subject to change without notice