Product Model
T5N400 UL TMA 400-2000..4000 4p FF N100%

Selling Points
- 1High Performance: Designed for demanding electrical environments with a rated current of 400A and short-circuit breaking capacity of 25 kA.
- 2Thermal Magnetic Protection: Combines thermal sensitivity for overload protection and magnetic performance for short-circuit safety.
- 3Compliance with Standards: Meets UL and IEC standards, ensuring reliability and safety in various applications.
- 4Versatile Voltage Rating: Operates at 240/480/600 VAC at 50/60 Hz (UL) and 220/230/300/400/415/440/500/660/690 VAC at 50/60 Hz (IEC).
- 5Compact Design: Measures 7.24 inches wide, 4.07 inches deep, and 8.07 inches high, making it easy to integrate into electrical panels.
Technical Specifications
Detailed engineering parameters based on manufacturer documentation
Parameter | Value | Parameter | Value |
---|---|---|---|
Environmental Information | 9AKK10103A1056 9AKK108467A6707 | Product Net Width | 186 mm |
Product Net Height | 205 mm | Product Net Depth / Length | 103.5 mm |
Product Net Weight | 4.15 kg | Product Main Type | SACE Tmax T |
Product Name | Moulded Case Circuit Breaker | Product Type | Automatic Circuit Breaker |
Suitable For | T5 | Suitable for Product Class | Moulded Case Circuit Breakers |
Version | F | Mechanical Durability | 20000 cycle 120 cycles per hour |
Number of Poles | 4 | Power Loss | at Rated Operating Conditions per Pole 19.5 W |
Rated Current (In) | 400 A | Rated Impulse Withstand Voltage (Uimp) | 8 kV |
Rated Insulation Voltage (Ui) | 1000 V | Rated Operational Voltage | 600 V AC 600 V DC |
Rated Ultimate Short-Circuit Breaking Capacity (Icu) | (240 V AC) 65 kA (480 V AC) 25 kA (600 V AC) 18 kA (500 V DC) 2 Poles in Series 25 kA (600 V DC) 3 Poles in Series 16 kA | Rated Uninterrupted Current (Iu) | 400 A |
Release | TMA | Release Type | TM |
Short-Circuit Performance Level | N | Standards | UL |
Sub-type | T5 | Terminal Connection Type | Fixed Circuit-Breakers Front |
Test Voltage Max (Utest) | 3500 V | Interrupting Rating acc. to UL489 | (240 V AC) 65 kA (480 V AC) 25 kA (600 V AC) 18 kA (500 V DC) 2 Poles in Series 25 kA (600 V DC) 3 Poles in Series 16 kA |
ETIM 8 | EC000228 - Power circuit-breaker for trafo/generator/installation protection | ETIM 9 | EC000228 - Power circuit-breaker for trafo/generator/installation protection |
WEEE Category | 5. Small Equipment (No External Dimension More Than 50 cm) | eClass | V11.1 : 27370409 |
Manufacturer ID | 1SDA060633R1 |
Specifications may be subject to change without notice