Product Model

TA200DU-110-V1000

In Stock
Last updated: 2025/4/22
ABB TA200DU-110-V1000

Selling Points

  • 1Reliable Motor Protection: Safeguards motors against overload and phase failures.
  • 2Manual/Automatic Reset: Selectable reset function for easy operation.
  • 3Trip-Free Mechanism: Ensures safe operation by preventing accidental tripping.
  • 4Temperature Compensation: Operates effectively in temperatures from -25 to 55°C.
  • 5Compact Design: Compact size of 104 mm width for easy installation.
Product Details
TA200DU-110-V1000
ABB

Technical Specifications

Detailed engineering parameters based on manufacturer documentation

ParameterValueParameterValue
Product Net Width
104 mm
Product Net Height
151 mm
Product Net Depth / Length
126 mm
Product Net Weight
0.76 kg
Setting Range
80 ... 110 A
Rated Operational Voltage
Auxiliary Circuit 440 V DC Auxiliary Circuit 500 V AC Main Circuit 690 V AC Main Circuit 440 V DC
Rated Operational Current (Ie)
110 A
Rated Frequency (f)
Auxiliary Circuit 50 Hz Auxiliary Circuit 60 Hz Auxiliary Circuit DC Main Circuit 60 Hz Main Circuit 50 Hz Main Circuit DC
Rated Impulse Withstand Voltage (Uimp)
Auxiliary Circuit 6 kV Main Circuit 6 kV
Rated Insulation Voltage (Ui)
690 V
Number of Poles
3P
Number of Auxiliary Contacts NC
1
Number of Auxiliary Contacts NO
1
Number of Protected Poles
3
Conventional Free-air Thermal Current (Ith)
Auxiliary Circuit NC 10 A Auxiliary Circuit NO 6 A
Rated Operational Current AC-15 (Ie)
(120 V) NC 3 A (120 V) NO 1.5 A (240 V) NC 3 A (240 V) NO 1.2 A (400 V) NC 0.75 A (400 V) NO 0.37 A (440 V) NC 0.75 A (440 V) NO 0.37 A (500 V) NC 0.3 A (500 V) NO 0.25 A
Rated Operational Current DC-13 (Ie)
(125 V) NC 0.25 A (125 V) NO 0.25 A (24 V) NC 1.25 A (24 V) NO 1.25 A (250 V) NC 0.12 A (250 V) NO 0.04 A (60 V) NC 0.25 A (60 V) NO 0.25 A
Degree of Protection
Housing IP20 Main Circuit Terminals IP00
Pollution Degree
3
Connecting Capacity Auxiliary Circuit
Flexible with Ferrule 1/2x 0.75 ... 2.5 mm² Flexible 1/2x 0.75 ... 2.5 mm² Rigid 1/2x 0.75 ... 4 mm²
Connecting Capacity Main Circuit
Hole Diameter > 10 mm² Rigid or Flexible with Cable Lug 1x 25 ... 120 mm²
Tightening Torque
Auxiliary Circuit 1 ... 1.3 N·m Main Circuit 25 N·m
Wire Stripping Length
Auxiliary Circuit 9 mm
Recommended Screw Driver
Auxiliary Circuit Pozidriv 1 Main Circuit Open Bars
Mounting Position
1 ... 6
Power Loss
at Rated Operating Conditions per Pole 2.5 ... 4.7 W
Suitable For
A145 A185 AF145 AF185 AF190 AF205
Standards
IEC/EN 60947-1 IEC/EN 60947-4-1 IEC/EN 60947-5-1 UL 60947-1 UL 60947-4-1
Maximum Operating Voltage UL/CSA
Main Circuit 600 V AC
Contact Rating UL/CSA
(NO:) B600 (NC:) C600
Connecting Capacity Main Circuit UL/CSA
Flexible 1x 4-0000 AWG Stranded 1x 4-0000 AWG
Connecting Capacity Auxiliary Circuit UL/CSA
Flexible 1/2x 18-14 AWG Stranded 1/2x 18-14 AWG
Tightening Torque UL/CSA
Auxiliary Circuit 12 in·lb Main Circuit 220 in·lb
Ambient Air Temperature
Operation -5 ... +40 °C Operation Compensated -5 ... +40 °C Storage -40 ... +70 °C
Ambient Air Temperature Compensation
Yes
Maximum Operating Altitude Permissible
2000 m
Resistance to Shock acc. to IEC 60068-2-27
11 ms Pulse 12g
RoHS Status
Following EU Directive 2011/65/EU and Amendment 2015/863 July 22, 2019
Toxic Substances Control Act - TSCA
2CMT2023-006525
Object Classification Code
F
ETIM 4
EC000106 - Thermal overload relay
ETIM 5
EC000106 - Thermal overload relay
ETIM 6
EC000106 - Thermal overload relay
ETIM 7
EC000106 - Thermal overload relay
ETIM 8
EC000106 - Thermal overload relay
eClass
V11.0 : 27371501
UNSPSC
39121520
IDEA Granular Category Code (IGCC)
5364 >> Overload relay
Manufacturer ID
1SAZ421301R1002

Specifications may be subject to change without notice