Product Model
TA200DU-135-V1000

Selling Points
- 1Reliable Motor Protection: Provides fast and reliable protection for motors against overload and phase failure.
- 2Adjustable Current Settings: Allows for adjustable current settings from 100A to 135A for customizable protection.
- 3Trip Class 10A: Ensures high-quality protection with a trip class of 10A.
- 4Automatic/Manual Reset: Offers selectable automatic or manual reset functions for easy operation.
- 5ATEX Compliant: Meets ATEX standards for use in hazardous environments.
Technical Specifications
Detailed engineering parameters based on manufacturer documentation
Parameter | Value | Parameter | Value |
---|---|---|---|
Product Net Width | 104 mm | Product Net Height | 151 mm |
Product Net Depth / Length | 126 mm | Product Net Weight | 0.76 kg |
Setting Range | 100 ... 135 A | Rated Operational Voltage | Auxiliary Circuit 440 V DC Auxiliary Circuit 500 V AC Main Circuit 690 V AC Main Circuit 440 V DC |
Rated Operational Current (Ie) | 135 A | Rated Frequency (f) | Auxiliary Circuit 50 Hz Auxiliary Circuit 60 Hz Auxiliary Circuit DC Main Circuit 60 Hz Main Circuit 50 Hz Main Circuit DC |
Rated Impulse Withstand Voltage (Uimp) | Auxiliary Circuit 6 kV Main Circuit 6 kV | Rated Insulation Voltage (Ui) | 690 V |
Number of Poles | 3P | Number of Auxiliary Contacts NC | 1 |
Number of Auxiliary Contacts NO | 1 | Number of Protected Poles | 3 |
Conventional Free-air Thermal Current (Ith) | Auxiliary Circuit NC 10 A Auxiliary Circuit NO 6 A | Rated Operational Current AC-15 (Ie) | (120 V) NC 3 A (120 V) NO 1.5 A (240 V) NC 3 A (240 V) NO 1.2 A (400 V) NC 0.75 A (400 V) NO 0.37 A (440 V) NC 0.75 A (440 V) NO 0.37 A (500 V) NC 0.3 A (500 V) NO 0.25 A |
Rated Operational Current DC-13 (Ie) | (125 V) NC 0.25 A (125 V) NO 0.25 A (24 V) NC 1.25 A (24 V) NO 1.25 A (250 V) NC 0.12 A (250 V) NO 0.04 A (60 V) NC 0.25 A (60 V) NO 0.25 A | Degree of Protection | Housing IP20 Main Circuit Terminals IP00 |
Pollution Degree | 3 | Connecting Capacity Auxiliary Circuit | Flexible with Ferrule 1/2x 0.75 ... 2.5 mm² Flexible 1/2x 0.75 ... 2.5 mm² Rigid 1/2x 0.75 ... 4 mm² |
Connecting Capacity Main Circuit | Hole Diameter > 10 mm² Rigid or Flexible with Cable Lug 1x 25 ... 120 mm² | Tightening Torque | Auxiliary Circuit 1 ... 1.3 N·m Main Circuit 25 N·m |
Wire Stripping Length | Auxiliary Circuit 9 mm | Recommended Screw Driver | Auxiliary Circuit Pozidriv 1 Main Circuit Open Bars |
Mounting Position | 1 ... 6 | Power Loss | at Rated Operating Conditions per Pole 3.3 ... 6.0 W |
Suitable For | A145 A185 AF145 AF185 AF190 AF205 | Standards | IEC/EN 60947-1 IEC/EN 60947-4-1 IEC/EN 60947-5-1 UL 60947-1 UL 60947-4-1 |
Maximum Operating Voltage UL/CSA | Main Circuit 600 V AC | Contact Rating UL/CSA | (NO:) B600 (NC:) C600 |
Connecting Capacity Main Circuit UL/CSA | Flexible 1x 4-0000 AWG Stranded 1x 4-0000 AWG | Connecting Capacity Auxiliary Circuit UL/CSA | Flexible 1/2x 18-14 AWG Stranded 1/2x 18-14 AWG |
Tightening Torque UL/CSA | Auxiliary Circuit 12 in·lb Main Circuit 220 in·lb | Ambient Air Temperature | Operation -5 ... +40 °C Operation Compensated -5 ... +40 °C Storage -40 ... +70 °C |
Ambient Air Temperature Compensation | Yes | Maximum Operating Altitude Permissible | 2000 m |
Resistance to Shock acc. to IEC 60068-2-27 | 11 ms Pulse 12g | RoHS Status | Following EU Directive 2011/65/EU and Amendment 2015/863 July 22, 2019 |
Toxic Substances Control Act - TSCA | 2CMT2023-006525 | Object Classification Code | F |
ETIM 4 | EC000106 - Thermal overload relay | ETIM 5 | EC000106 - Thermal overload relay |
ETIM 6 | EC000106 - Thermal overload relay | ETIM 7 | EC000106 - Thermal overload relay |
ETIM 8 | EC000106 - Thermal overload relay | eClass | V11.0 : 27371501 |
UNSPSC | 39121520 | IDEA Granular Category Code (IGCC) | 5364 >> Overload relay |
Manufacturer ID | 1SAZ421301R1003 |
Specifications may be subject to change without notice