Product Model
XT1S160 TMD50/500 PMP 3P

Selling Points
- 1High Short-Circuit Breaking Capacity: The XT1S160 TMD50/500 3P circuit breaker offers exceptional short-circuit breaking capacities up to 63.75 kA, ensuring reliable operation under critical conditions.
- 2Thermal-Magnetic Release: Equipped with a TMD release, this circuit breaker provides both thermal and magnetic protection, ensuring safe operation and minimizing the risk of electrical faults.
- 3Robust Design: Constructed with high-quality materials, the XT1S160 TMD50/500 3P is designed to withstand harsh environmental conditions, making it suitable for various industrial applications.
- 4Compliance with IEC Standards: Meets IEC standards for safety and performance, ensuring that the circuit breaker operates within specified parameters and maintains high levels of reliability.
- 5Front Terminal Connection: Features front terminals for easy installation and maintenance, reducing downtime and enhancing overall efficiency in power distribution systems.
Technical Specifications
Detailed engineering parameters based on manufacturer documentation
Parameter | Value | Parameter | Value |
---|---|---|---|
Environmental Information | 9AKK108467A6707 | Product Main Type | SACE Tmax XT |
Product Name | Moulded Case Circuit Breaker | Product Type | Automatic Circuit Breaker |
Version | P | Current Type | AC/DC |
Electrical Durability | 8000 cycle 120 cycles per hour | Mechanical Durability | 25000 cycle 240 cycles per hour |
Number of Poles | 3P | Power Loss | at Rated Operating Conditions per Pole 5.0 W |
Rated Current (In) | 50 A | Rated Impulse Withstand Voltage (Uimp) | 8 kV |
Rated Insulation Voltage (Ui) | 800 V | Rated Operational Voltage | 690 V AC 500 V DC |
Rated Service Short-Circuit Breaking Capacity (Ics) | (220 V AC) 63.75 kA (230 V AC) 63.75 kA (240 V AC) 63.75 kA (380 V AC) 50 kA (415 V AC) 37.5 kA (440 V AC) 25 kA (500 V AC) 18 kA (525 V AC) 17.5 kA (690 V AC) 5 kA (250 V DC) 2 Poles in Series 50 kA (500 V DC) 3 Poles in Series 50 kA | Rated Ultimate Short-Circuit Breaking Capacity (Icu) | (220 V AC) 85 kA (230 V AC) 85 kA (240 V AC) 85 kA (380 V AC) 50 kA (415 V AC) 50 kA (440 V AC) 50 kA (500 V AC) 36 kA (525 V AC) 35 kA (690 V AC) 8 kA (250 V DC) 2 Poles in Series 50 kA (500 V DC) 3 Poles in Series 50 kA |
Rated Uninterrupted Current (Iu) | 160 A | Release | TMD |
Release Type | TM | Remarks | ATLAS |
Short-Circuit Performance Level | S | Standards | IEC60947-2 GB/T 14028.2 |
Sub-type | XT1 | Terminal Connection Type | Plug-In Circuit-Breakers |
WEEE Category | 5. Small Equipment (No External Dimension More Than 50 cm) | Manufacturer ID | 2TFH100587R1001 |
Specifications may be subject to change without notice