Technical Specifications
Detailed engineering parameters based on manufacturer documentation
Parameter | Value | Parameter | Value |
---|---|---|---|
Environmental Information | 9AKK108467A6707 | Product Net Width | 90 mm |
Product Net Height | 130 mm | Product Net Depth / Length | 82.5 mm |
Product Net Weight | 1.1 kg | Circuit Breaker Type to be Associated | Motor Protection |
Product Main Type | SACE Tmax XT | Product Name | Moulded Case Circuit Breaker |
Product Type | Automatic Circuit Breaker | Suitable for Product Class | SACE Tmax XT |
Version | F | CAD Dimensional Drawing | 1SDH002230A1001 |
Connecting Capacity Main Circuit | Busbar 32.5..100 mm² | Current Type | AC/DC |
Electrical Durability | 120 cycles per hour 8000 cycle | Mechanical Durability | 240 cycles per hour 25000 cycle |
Number of Poles | 3P | Opening Time | CB with SOR 15 ms CB with UVR 15 ms |
Order Multiple | 1 piece | Power Loss | at Rated Operating Conditions per Pole 8.1 W |
Rated Current (In) | 80 A | Rated Instantaneous Short-Circuit Current Setting (Ii) | 240â¦880 A |
Rated Operational Voltage | 600 V AC | Rated Uninterrupted Current (Iu) | 125 A |
Rated Voltage (Ur) | 600 V | Recommended Screw Driver | Main Circuit M6 |
Release | MA | Release Type | M |
Short-Circuit Performance Level | H | Standards | UL489 |
Sub-type | XT2 | Terminal Connection Type | Front |
Terminal Type | Bolt | Tightening Torque | 6 N·m |
Interrupting Rating acc. to UL489 | (240 V AC) 150 kA (480 V AC) 65 kA (600 V AC) 25 kA (250 V DC) 2 Poles in Series 65 kA (500 V DC) 3 Poles in Series 65 kA | ETIM 8 | EC000228 - Power circuit-breaker for trafo/generator/installation protection |
ETIM 9 | EC000228 - Power circuit-breaker for trafo/generator/installation protection | IDEA Granular Category Code (IGCC) | 4932 >> 3 Pole Non-Interchangeable Trip Electronic Circuit Breakers |
Object Classification Code | Q | UNSPSC | 39121616 |
WEEE Category | 5. Small Equipment (No External Dimension More Than 50 cm) | eClass | V11.1 : 27370409 |
Manufacturer ID | 1SDA074888R1 |
Specifications may be subject to change without notice