Product Model

XT2L 125 TMA 90-450..900 4p F F UL/CSA

In Stock
Last updated: 2025/4/18
ABB XT2L 125 TMA 90-450..900 4p F F UL/CSA

Selling Points

  • 1Adjustable Thermal-Magnetic Trip Unit: Customize settings for over-current and short-circuit protection.
  • 2Compliant with UL and CSA Standards: Meets rigorous safety standards for electrical installations.
  • 34-Pole Design: Suitable for a variety of electrical applications requiring high reliability.
  • 4High Short-Circuit Rating: Handles 100kA at 480VAC, ensuring robust protection against electrical surges.
  • 5Durable Construction: Designed for 25,000 operations at no load, ensuring long-lasting performance.
Product Details
XT2L 125 TMA 90-450..900 4p F F UL/CSA
ABB

Technical Specifications

Detailed engineering parameters based on manufacturer documentation

ParameterValueParameterValue
Environmental Information
9AKK108467A6707
Product Net Width
120 mm
Product Net Height
130 mm
Product Net Depth / Length
82.5 mm
Product Net Weight
1.45 kg
Circuit Breaker Type to be Associated
Power Distribution
Product Main Type
SACE Tmax XT
Product Name
Moulded Case Circuit Breaker
Product Type
Automatic Circuit Breaker
Suitable for Product Class
SACE Tmax XT
Version
F
CAD Dimensional Drawing
1SDH002230A1002
Connecting Capacity Main Circuit
Busbar 32.5..100 mm²
Current Type
AC/DC
Electrical Durability
120 cycles per hour 8000 cycle
Mechanical Durability
240 cycles per hour 25000 cycle
Number of Poles
4P
Opening Time
CB with SOR 15 ms CB with UVR 15 ms
Order Multiple
1 piece
Power Loss
at Rated Operating Conditions per Pole 6.6 W
Rated Current (In)
90 A
Rated Instantaneous Short-Circuit Current Setting (Ii)
450…900 A
Rated Operational Voltage
600 V AC 500 V DC
Rated Uninterrupted Current (Iu)
125 A
Rated Voltage (Ur)
600 V
Recommended Screw Driver
Main Circuit M6
Release
TMA
Release Type
TM
Setting Range
63...90 A
Short-Circuit Performance Level
L
Standards
UL489
Sub-type
XT2
Terminal Connection Type
Front
Terminal Type
Bolt
Tightening Torque
6 N·m
Interrupting Rating acc. to UL489
(240 V AC) 200 kA (480 V AC) 100 kA (600 V AC) 35 kA (250 V DC) 2 Poles in Series 75 kA (500 V DC) 3 Poles in Series 75 kA
ETIM 8
EC000228 - Power circuit-breaker for trafo/generator/installation protection
ETIM 9
EC000228 - Power circuit-breaker for trafo/generator/installation protection
IDEA Granular Category Code (IGCC)
4927 >> Molded case circuit breakers
Object Classification Code
Q
UNSPSC
39121616
WEEE Category
5. Small Equipment (No External Dimension More Than 50 cm)
eClass
V11.1 : 27370409
Manufacturer ID
1SDA074841R1

Specifications may be subject to change without notice