Product Model
XT2N 160 Ekip Dip LIG In=100A 4p F F

Selling Points
- 1Designed for reliable and efficient power distribution in AC applications.
- 2Features a solid-state release mechanism for fast and precise circuit interruption.
- 3Equipped with front terminals for easy installation and maintenance.
- 4Meets IEC standards for safety and performance, ensuring top-notch quality.
- 5Built to withstand 120 cycles per hour with 8000 cycles electrical durability and 240 cycles per hour with 25000 cycles mechanical durability.
Technical Specifications
Detailed engineering parameters based on manufacturer documentation
Parameter | Value | Parameter | Value |
---|---|---|---|
Environmental Information | 9AKK108467A6707 | Product Net Width | 120 mm |
Product Net Height | 130 mm | Product Net Depth / Length | 82.5 mm |
Product Net Weight | 1.5 kg | Circuit Breaker Type to be Associated | Power Distribution |
Product Main Type | SACE Tmax XT | Product Name | Moulded Case Circuit Breaker |
Product Type | Automatic Circuit Breaker | Version | F |
CAD Dimensional Drawing | 1SDH002230A1002 | Current Type | AC |
Electrical Durability | 120 cycles per hour 8000 cycle | Mechanical Durability | 240 cycles per hour 25000 cycle |
Number of Poles | 4P | Order Multiple | 1 piece |
Power Loss | at Rated Operating Conditions per Pole 8.1 W | Rated Current (In) | 100 A |
Rated Impulse Withstand Voltage (Uimp) | 8 kV | Rated Insulation Voltage (Ui) | 1000 V |
Rated Operational Voltage | 690 V AC | Rated Service Short-Circuit Breaking Capacity (Ics) | (220 V AC) 65 kA (230 V AC) 65 kA (240 V AC) 65 kA (380 V AC) 36 kA (415 V AC) 36 kA (440 V AC) 36 kA (500 V AC) 30 kA (525 V AC) 20 kA (690 V AC) 10 kA |
Rated Ultimate Short-Circuit Breaking Capacity (Icu) | (220 V AC) 65 kA (230 V AC) 65 kA (240 V AC) 65 kA (380 V AC) 36 kA (415 V AC) 36 kA (440 V AC) 36 kA (500 V AC) 30 kA (525 V AC) 20 kA (690 V AC) 10 kA | Rated Uninterrupted Current (Iu) | 160 A |
Release | Ekip Dip LIG | Release Type | EL |
Short-Circuit Performance Level | N | Standards | IEC60947-2 |
Sub-type | XT2 | Terminal Connection Type | Front |
ETIM 8 | EC000228 - Power circuit-breaker for trafo/generator/installation protection | ETIM 9 | EC000228 - Power circuit-breaker for trafo/generator/installation protection |
Object Classification Code | Q | WEEE Category | 5. Small Equipment (No External Dimension More Than 50 cm) |
eClass | V11.1 : 27370409 | Manufacturer ID | 1SDA100028R1 |