Product Model

XT2N160 TMA100/1000 WMP 4P

In Stock
Last updated: 2025/4/24
ABB XT2N160 TMA100/1000 WMP 4P

Selling Points

  • 1The XT2N 160 TMA 100-1000 4P circuit breaker offers exceptional short-circuit breaking capacities up to 65 kA for AC and 36 kA for DC, ensuring reliable operation under demanding conditions.
  • 2Constructed with a thermomagnetic release (TMA) mechanism, this circuit breaker provides reliable and fast operation, ensuring safety and efficiency in power distribution systems.
  • 3Compatible with both AC and DC voltages, the XT2N 160 TMA 100-1000 4P can handle a wide range of operational voltages from 500 V DC to 690 V AC, making it versatile for various applications.
  • 4Designed to withstand 120 cycles per hour and a total of 8000 cycles, this circuit breaker ensures long-lasting performance and reliability in heavy-duty environments.
  • 5Meets IEC standards, ensuring compliance with international safety and performance regulations, providing peace of mind for users.
Product Details
XT2N160 TMA100/1000 WMP 4P
ABB

Technical Specifications

Detailed engineering parameters based on manufacturer documentation

ParameterValueParameterValue
Environmental Information
9AKK108467A6707
Product Main Type
SACE Tmax XT
Product Name
Moulded Case Circuit Breaker
Product Type
Automatic Circuit Breaker
Version
W
Current Type
AC/DC
Electrical Durability
8000 cycle 120 cycles per hour
Mechanical Durability
25000 cycle 240 cycles per hour
Number of Poles
4P
Power Loss
at Rated Operating Conditions per Pole 9.5 W
Rated Current (In)
100 A
Rated Impulse Withstand Voltage (Uimp)
8 kV
Rated Insulation Voltage (Ui)
1000 V
Rated Operational Voltage
690 V AC 500 V DC
Rated Service Short-Circuit Breaking Capacity (Ics)
(220 V AC) 65 kA (230 V AC) 65 kA (240 V AC) 65 kA (380 V AC) 36 kA (415 V AC) 36 kA (440 V AC) 36 kA (500 V AC) 30 kA (525 V AC) 20 kA (690 V AC) 10 kA (250 V DC) 2 Poles in Series 36 kA (500 V DC) 3 Poles in Series 36 kA
Rated Ultimate Short-Circuit Breaking Capacity (Icu)
(220 V AC) 65 kA (230 V AC) 65 kA (240 V AC) 65 kA (380 V AC) 36 kA (415 V AC) 36 kA (440 V AC) 36 kA (500 V AC) 30 kA (525 V AC) 20 kA (690 V AC) 10 kA (250 V DC) 2 Poles in Series 36 kA (500 V DC) 3 Poles in Series 36 kA
Rated Uninterrupted Current (Iu)
160 A
Release
TMA
Release Type
TM
Remarks
ATLAS
Short-Circuit Performance Level
N
Standards
IEC60947-2 GB/T 14028.2
Sub-type
XT2
Terminal Connection Type
Withdrawable Circuit-Breakers
WEEE Category
5. Small Equipment (No External Dimension More Than 50 cm)
Manufacturer ID
2TFH102381R1001