Product Model
XT2S 125 Ekip LSIG In=10A 4p F F UL/CSA

Selling Points
- 1The XT2S 125 Ekip LSIG integrates multiple protection functions, including overload, short-circuit with time delay, and earth fault protection.
- 2With adjustable settings for overload and short-circuit protection, this circuit breaker can be customized to meet specific application needs.
- 3It features high breaking capacities of up to 50 kA at 500 Vdc and 22 kA at 600 Vac, ensuring reliable operation under extreme conditions.
- 4The Ekip Touch trip unit offers an intuitive LCD display and easy-to-use interface, simplifying installation and maintenance.
- 5The XT2S 125 Ekip LSIG is compliant with UL 489 and CSA C22.2 standards, ensuring it meets rigorous safety and performance requirements.
Technical Specifications
Detailed engineering parameters based on manufacturer documentation
Parameter | Value | Parameter | Value |
---|---|---|---|
Environmental Information | 9AKK108467A6707 | Product Net Width | 120 mm |
Product Net Height | 130 mm | Product Net Depth / Length | 82.5 mm |
Product Net Weight | 1.6 kg | Circuit Breaker Type to be Associated | Power Distribution |
Product Main Type | SACE Tmax XT | Product Name | Moulded Case Circuit Breaker |
Product Type | Automatic Circuit Breaker | Suitable for Product Class | SACE Tmax XT |
Version | F | CAD Dimensional Drawing | 1SDH002230A1002 |
Connecting Capacity Main Circuit | Busbar 32.5..100 mm² | Current Type | AC |
Electrical Durability | 120 cycles per hour 8000 cycle | Mechanical Durability | 240 cycles per hour 25000 cycle |
Number of Poles | 4P | Opening Time | CB with SOR 15 ms CB with UVR 15 ms |
Order Multiple | 1 piece | Power Loss | at Rated Operating Conditions per Pole 0.10 W |
Rated Current (In) | 10 A | Rated Frequency (f) | 50/60 Hz |
Rated Insulation Voltage (Ui) | 1000 V AC | Rated Operational Voltage | 690 V AC |
Rated Uninterrupted Current (Iu) | 160 A | Rated Voltage (Ur) | 690 V AC |
Recommended Screw Driver | Main Circuit M6 | Release | Ekip LSIG |
Release Type | EL | Short-Circuit Performance Level | S |
Standards | UL489 | Sub-type | XT2 |
Terminal Connection Type | Front | Terminal Type | Bolt |
Tightening Torque | 6 N·m | Interrupting Rating acc. to UL489 | (240 V AC) 100 A (480 V AC) 35 A (600 V AC) 22 A |
ETIM 8 | EC000228 - Power circuit-breaker for trafo/generator/installation protection | ETIM 9 | EC000228 - Power circuit-breaker for trafo/generator/installation protection |
IDEA Granular Category Code (IGCC) | 4934 >> 4 Pole Non-Interchangeable Trip Electronic Circuit Breakers | Object Classification Code | Q |
UNSPSC | 39121616 | WEEE Category | 5. Small Equipment (No External Dimension More Than 50 cm) |
eClass | V11.1 : 27370409 | Manufacturer ID | 1SDA075015R1 |
Specifications may be subject to change without notice