Product Model
XT2S 160 Ekip Dip LIG In=63A 4p F F

Selling Points
- 1High Electrical Durability: Withstands 120 cycles per hour and 8000 cycles, ensuring long-lasting performance.
- 2Solid-State Release: Features a reliable EL release type for efficient short-circuit performance.
- 3Compact Design: Measures 130 mm x 145 mm x 208 mm, making it easy to integrate into various systems.
- 4IEC 60947 Compliance: Meets international standards for safety and performance.
- 5Versatile Application: Suitable for transformer, generator, and installation protection in AC systems.
Technical Specifications
Detailed engineering parameters based on manufacturer documentation
Parameter | Value | Parameter | Value |
---|---|---|---|
Environmental Information | 9AKK108467A6707 | Product Net Width | 120 mm |
Product Net Height | 130 mm | Product Net Depth / Length | 82.5 mm |
Product Net Weight | 1.5 kg | Circuit Breaker Type to be Associated | Power Distribution |
Product Main Type | SACE Tmax XT | Product Name | Moulded Case Circuit Breaker |
Product Type | Automatic Circuit Breaker | Version | F |
CAD Dimensional Drawing | 1SDH002230A1002 | Current Type | AC |
Electrical Durability | 120 cycles per hour 8000 cycle | Mechanical Durability | 240 cycles per hour 25000 cycle |
Number of Poles | 4P | Order Multiple | 1 piece |
Power Loss | at Rated Operating Conditions per Pole 1.7 W | Rated Current (In) | 63 A |
Rated Impulse Withstand Voltage (Uimp) | 8 kV | Rated Insulation Voltage (Ui) | 1000 V |
Rated Operational Voltage | 690 V AC | Rated Service Short-Circuit Breaking Capacity (Ics) | (220 V AC) 85 kA (230 V AC) 85 kA (240 V AC) 85 kA (380 V AC) 50 kA (415 V AC) 50 kA (440 V AC) 50 kA (500 V AC) 36 kA (525 V AC) 25 kA (690 V AC) 12 kA |
Rated Ultimate Short-Circuit Breaking Capacity (Icu) | (220 V AC) 85 kA (230 V AC) 85 kA (240 V AC) 85 kA (380 V AC) 50 kA (415 V AC) 50 kA (440 V AC) 50 kA (500 V AC) 36 kA (525 V AC) 25 kA (690 V AC) 12 kA | Rated Uninterrupted Current (Iu) | 160 A |
Release | Ekip Dip LIG | Release Type | EL |
Short-Circuit Performance Level | S | Standards | IEC60947-2 |
Sub-type | XT2 | Terminal Connection Type | Front |
ETIM 8 | EC000228 - Power circuit-breaker for trafo/generator/installation protection | ETIM 9 | EC000228 - Power circuit-breaker for trafo/generator/installation protection |
Object Classification Code | Q | WEEE Category | 5. Small Equipment (No External Dimension More Than 50 cm) |
eClass | V11.1 : 27370409 | Manufacturer ID | 1SDA100057R1 |
Specifications may be subject to change without notice