Product Model
XT3N 225 TMF 70-700 4p F F UL/CSA

Selling Points
- 150kA (240Vac; UL489) and 25kA (480Vac; UL489) for reliable short-circuit protection.
- 2Combines thermal and magnetic protection for comprehensive overload and short-circuit protection.
- 3Meets UL 489 and CSA C22.2 standards, ensuring safety and reliability in industrial applications.
- 4Modular structure with one-fits-all accessories for easy upgrades and customization.
- 5Trip units measure electrical parameters with 1% accuracy certification for effective energy management.
Technical Specifications
Detailed engineering parameters based on manufacturer documentation
Parameter | Value | Parameter | Value |
---|---|---|---|
Environmental Information | 9AKK108467A6707 | Product Net Width | 140 mm |
Product Net Height | 150 mm | Product Net Depth / Length | 70 mm |
Product Net Weight | 2.1 kg | Circuit Breaker Type to be Associated | Power Distribution |
Product Main Type | SACE Tmax XT | Product Name | Moulded Case Circuit Breaker |
Product Type | Automatic Circuit Breaker | Suitable for Product Class | SACE Tmax XT |
Version | F | CAD Dimensional Drawing | 1SDH001295R0483 |
Connecting Capacity Main Circuit | Busbar 85..192 mm² | Current Type | AC/DC |
Electrical Durability | 120 cycles per hour 8000 cycle | Mechanical Durability | 240 cycles per hour 25000 cycle |
Number of Poles | 4P | Opening Time | CB with SOR 15 ms CB with UVR 15 ms |
Order Multiple | 1 piece | Power Loss | at Rated Operating Conditions per Pole 3.7 W |
Rated Current (In) | 70 A | Rated Instantaneous Short-Circuit Current Setting (Ii) | 700 A |
Rated Operational Voltage | 600Y/347 V AC 500 V DC | Rated Uninterrupted Current (Iu) | 225 A |
Rated Voltage (Ur) | 600Y/347 V | Recommended Screw Driver | Main Circuit M8 |
Release | TMF | Release Type | TM |
Setting Range | 70 A | Short-Circuit Performance Level | N |
Standards | UL489 | Sub-type | XT3 |
Terminal Connection Type | Front | Terminal Type | Bolt |
Tightening Torque | 8 N·m | Interrupting Rating acc. to UL489 | (240 V AC) 50 kA (480 V AC) 25 kA (600Y / 347 V AC) 10 kA (250 V DC) 2 Poles in Series 25 kA (500 V DC) 3 Poles in Series 25 kA |
ETIM 8 | EC000228 - Power circuit-breaker for trafo/generator/installation protection | ETIM 9 | EC000228 - Power circuit-breaker for trafo/generator/installation protection |
IDEA Granular Category Code (IGCC) | 4927 >> Molded case circuit breakers | Object Classification Code | Q |
UNSPSC | 39121616 | WEEE Category | 5. Small Equipment (No External Dimension More Than 50 cm) |
eClass | V11.1 : 27370409 | Manufacturer ID | 1SDA075120R1 |
Specifications may be subject to change without notice