Product Model
XT3S 250 MA 100 Im=600...1200 3p F F

Selling Points
- 1Designed for reliable operation in demanding electrical environments.
- 2Ensures safe and efficient disconnection during short-circuit conditions.
- 3Meets rigorous safety and performance requirements for electrical installations.
- 4Suitable for both AC and DC applications, including motor protection.
- 5Built with robust materials to withstand up to 25,000 mechanical operations.
Technical Specifications
Detailed engineering parameters based on manufacturer documentation
Parameter | Value | Parameter | Value |
---|---|---|---|
Environmental Information | 9AKK108467A6707 | Product Net Width | 105 mm |
Product Net Height | 150 mm | Product Net Depth / Length | 70 mm |
Product Net Weight | 1.7 kg | Circuit Breaker Type to be Associated | Motor Protection |
Product Main Type | SACE Tmax XT | Product Name | Moulded Case Circuit Breaker |
Product Type | Automatic Circuit Breaker | Version | F |
CAD Dimensional Drawing | 1SDH001295R0409 | Connecting Capacity Main Circuit | Busbar 85..192 mm² |
Current Type | AC/DC | Electrical Durability | 120 cycles per hour 8000 cycle |
Mechanical Durability | 240 cycles per hour 25000 cycle | Number of Poles | 3P |
Opening Time | CB with SOR 15 ms CB with UVR 15 ms | Order Multiple | 1 piece |
Power Loss | at Rated Operating Conditions per Pole 5.6 W | Rated Current (In) | 100 A |
Rated Frequency (f) | 50 / 60 Hz | Rated Impulse Withstand Voltage (Uimp) | 8 kV |
Rated Instantaneous Short-Circuit Current Setting (Ii) | 600â¦1200 A | Rated Insulation Voltage (Ui) | 800 V |
Rated Operational Voltage | 690 V AC 500 V DC | Rated Service Short-Circuit Breaking Capacity (Ics) | (220 V AC) 50 kA (230 V AC) 50 kA (240 V AC) 50 kA (380 V AC) 27 kA (415 V AC) 36 kA (440 V AC) 20 kA (500 V AC) 15 kA (525 V AC) 10 kA (690 V AC) 3 kA (250 V DC) 2 Poles in Series 27 kA (500 V DC) 3 Poles in Series 37.5 kA |
Rated Ultimate Short-Circuit Breaking Capacity (Icu) | (220 V AC) 85 kA (230 V AC) 85 kA (240 V AC) 85 kA (380 V AC) 50 kA (415 V AC) 50 kA (440 V AC) 40 kA (500 V AC) 30 kA (525 V AC) 20 kA (690 V AC) 6 kA (250 V DC) 2 Poles in Series 36 kA (500 V DC) 3 Poles in Series 50 kA | Rated Uninterrupted Current (Iu) | 250 A |
Rated Voltage (Ur) | 690 V | Recommended Screw Driver | Main Circuit M8 |
Release | MA | Release Type | M |
Short-Circuit Performance Level | S | Standards | IEC60947-2 |
Sub-type | XT3 | Terminal Connection Type | Front |
Terminal Type | Bolt | Tightening Torque | 8 N·m |
ETIM 8 | EC000228 - Power circuit-breaker for trafo/generator/installation protection | ETIM 9 | EC000228 - Power circuit-breaker for trafo/generator/installation protection |
Object Classification Code | Q | UNSPSC | 39120000 |
WEEE Category | 5. Small Equipment (No External Dimension More Than 50 cm) | eClass | V11.1 : 27370409 |
Manufacturer ID | 1SDA068279R1 |
Specifications may be subject to change without notice