Product Model

XT4N 250 Ekip LSI In=250A 3p F F

In Stock
Last updated: 2025/4/25
ABB XT4N 250 Ekip LSI In=250A 3p F F

Selling Points

  • 1Robust Performance: Designed for high-demand environments with mechanical endurance up to 25,000 cycles and electrical endurance of 8,000 cycles per hour.
  • 2Precise Trip Action: Features a solid-state release mechanism (EKIP-LSI) for precise trip action and rapid response times under short-circuit conditions.
  • 3Compliance and Safety: Adheres to international standards (IEC60947-2) ensuring reliability and safety in operation.
  • 4Efficient Handling: Supports efficient handling of electrical faults and overcurrent situations typical in power distribution systems.
  • 5Durable Design: Operates effectively within a frequency range of 50/60 Hz and is rated for a maximum operational voltage of 690V AC.
Product Details
XT4N 250 Ekip LSI In=250A 3p F F
ABB

Technical Specifications

Detailed engineering parameters based on manufacturer documentation

ParameterValueParameterValue
Environmental Information
9AKK108467A6707
Product Net Width
105 mm
Product Net Height
160 mm
Product Net Depth / Length
82.5 mm
Product Net Weight
2.323 kg
Circuit Breaker Type to be Associated
Power Distribution
Product Main Type
SACE Tmax XT
Product Name
Moulded Case Circuit Breaker
Product Type
Automatic Circuit Breaker
Version
F
CAD Dimensional Drawing
1SDH002230A1003
Connecting Capacity Main Circuit
Busbar 85..200 mm²
Current Type
AC
Electrical Durability
120 cycles per hour 8000 cycle
Mechanical Durability
240 cycles per hour 25000 cycle
Number of Poles
3P
Opening Time
CB with SOR 15 ms CB with UVR 15 ms
Order Multiple
1 piece
Power Loss
at Rated Operating Conditions per Pole 16.40 W
Rated Current (In)
250 A
Rated Frequency (f)
50/60 Hz
Rated Impulse Withstand Voltage (Uimp)
8 kV
Rated Insulation Voltage (Ui)
1000 V AC
Rated Operational Voltage
690 V AC
Rated Service Short-Circuit Breaking Capacity (Ics)
(220 V AC) 65 kA (230 V AC) 65 kA (240 V AC) 65 kA (380 V AC) 36 kA (415 V AC) 36 kA (440 V AC) 36 kA (500 V AC) 30 kA (525 V AC) 20 kA (690 V AC) 10 kA
Rated Ultimate Short-Circuit Breaking Capacity (Icu)
(220 V AC) 65 kA (230 V AC) 65 kA (240 V AC) 65 kA (380 V AC) 36 kA (415 V AC) 36 kA (440 V AC) 36 kA (500 V AC) 30 kA (525 V AC) 20 kA (690 V AC) 10 kA
Rated Uninterrupted Current (Iu)
250 A
Rated Voltage (Ur)
690 V AC
Recommended Screw Driver
Main Circuit M8
Release
Ekip LSI
Release Type
EL
Short-Circuit Performance Level
N
Standards
IEC60947-2
Sub-type
XT4
Terminal Connection Type
Front
Terminal Type
Bolt
Tightening Torque
8 N·m
ETIM 8
EC000228 - Power circuit-breaker for trafo/generator/installation protection
ETIM 9
EC000228 - Power circuit-breaker for trafo/generator/installation protection
IDEA Granular Category Code (IGCC)
4932 >> 3 Pole Non-Interchangeable Trip Electronic Circuit Breakers
Object Classification Code
Q
UNSPSC
39121616
WEEE Category
5. Small Equipment (No External Dimension More Than 50 cm)
eClass
V11.1 : 27370409
Manufacturer ID
1SDA068136R1

Specifications may be subject to change without notice