Product Model
lfr-3/4-d-di-maxi-a

Selling Points
- 1The LFR-3/4-D-DI-MAXI-A features a 40 μm filtration grade, ensuring high-quality compressed air for your industrial needs.
- 2This unit offers a pressure regulation range of 0.5 to 12 bar, allowing for precise control over your pneumatic system.
- 3The fully automatic condensate drain ensures efficient operation and minimizes downtime, making it perfect for continuous use.
- 4Constructed with a metal bowl guard and die-cast zinc housing, this unit provides durability and resistance to corrosion, ensuring long-lasting performance.
- 5The LFR-3/4-D-DI-MAXI-A can be installed in-line or vertically, offering flexibility in your pneumatic system setup.
Technical Specifications
Detailed engineering parameters based on manufacturer documentation
Parameter | Value | Parameter | Value |
---|---|---|---|
Size | Maxi | Series | D |
Actuator lock | Rotary knob with detent | Mounting position | Vertical +/- 5° |
Grade of filtration | 40μm | Condensate drain | Fully automatic |
Structural design | Filter regulator with pressure gauge | Max. condensate volume | 43ml |
Bowl guard | Metal bowl guard | Symbol | 00991587 |
Pressure gauge | with pressure gauge | Operating pressure | 2bar 12bar |
Pressure regulation range | 0.5bar 12bar | Max. pressure hysteresis | 5.8psi |
Standard nominal flow rate | 6800l/min | Operating medium | Compressed air as per ISO 8573-1:2010 [7:9:-] Inert gas |
Corrosion resistance class (CRC) | 2 - Moderate corrosion stress | LABS (PWIS) conformity | VDMA24364-B1/B2-L |
Storage temperature | -10°C 60°C | Air quality class at the output | Compressed air as per ISO 8573-1:2010 [7:8:4] Inert gas |
Temperature of medium | 5°C 60°C | Ambient temperature | 5°C 60°C |
Product weight | 1670g | Type of mounting | Line installation |
Pneumatic connection 1 | G3/4 | Pneumatic connection 2 | G3/4 |
Note on materials | RoHS-compliant | Housing material | Die-cast zinc |
Material of bowl | PC | Manufacturer ID | 192392 |
Specifications may be subject to change without notice