Product Model
ms6-ee

Selling Points
- 1The Festo MS6-EE shut off valve is electrically actuated, ensuring precise control over compressed air flow with a 3/2-way, closed, monostable valve function.
- 2This valve features a standard nominal flow rate of 7000 l/min, making it suitable for various industrial applications requiring high airflow.
- 3The MS6-EE is designed with a robust housing made from PA-reinforced materials, ensuring durability and resistance to corrosion, with a corrosion resistance class of CRC 1 - Low corrosion stress.
- 4The valve operates within a wide temperature range of -10°C to 60°C and has an ambient temperature range of -5°C to 50°C, making it versatile for different environments.
- 5The MS6-EE shut off valve is equipped with a pressure sensor and LCD display, providing real-time monitoring and control options, enhancing operational efficiency.
Technical Specifications
Detailed engineering parameters based on manufacturer documentation
Parameter | Value | Parameter | Value |
---|---|---|---|
Structural design | Piston gate valve | Actuation type | Electrical |
Exhaust air function | Without flow control option | Manual override | Detenting None Non-detenting |
Reset method | Mechanical spring | Type of control | Pilot-controlled |
Valve function | 3/2, closed, monostable | Pressure gauge | G1/4 prepared with pressure sensor with pressure gauge |
Operating pressure | 4bar 18bar | Standard nominal flow rate | 2600l/min 7000l/min |
Duty cycle | 100% | Coil characteristics | 110 V AC: 50/60 Hz, initial power 3.0 VA, holding power 2.4 VA 230 V AC: 50/60 Hz, initial power 3.0 VA, holding power 2.4 VA 24 V DC: 1.5 W 24 V DC: 2.5 W |
Operating medium | Compressed air as per ISO 8573-1:2010 [7:4:4] Inert gas | Information on operating and pilot media | Operation with oil lubrication possible (required for further use) |
Corrosion resistance class (CRC) | 2 - Moderate corrosion stress | Note on materials | RoHS-compliant |
LABS (PWIS) conformity | VDMA24364-B1/B2-L | Temperature of medium | -10°C 60°C |
Degree of protection | IP65 | Ambient temperature | -10°C 60°C |
Certification | c UL us - Recognized (OL) | KC characters | KC EMC |
CE marking (see declaration of conformity) | As per EU EMC directive as per EU explosion protection directive (ATEX) As per EU low voltage directive As per EU RoHS directive | UKCA marking (see declaration of conformity) | To UK instructions for EMC acc. to UK EX instructions To UK RoHS instructions To UK instructions for electrical equipment |
Explosion protection certification outside the EU | EPL Dc (GB) EPL Gc (GB) | Explosion prevention and protection | Zone 2 (ATEX) Zone 2 (UKEX) Zone 22 (ATEX) Zone 22 (UKEX) |
ATEX category gas | II 3G | ATEX category for dust | II 3D |
Type of ignition protection for gas | Ex nA IIC T4 X Gc | Type of (ignition) protection for dust | Ex tc IIIC T105°C IP65 Dc X |
Explosive ambient temperature | -10°C <= Ta <= +60°C | For use in the food industry | See supplementary material information |
Type of mounting | Optionally: Line installation With accessories | Mounting position | Any |
Flow direction | Non-reversible | Product weight | 740g |
Pneumatic connection 3 | G1/2 | Pilot air supply port | Internal |
Seals material | NBR | Housing material | Die-cast aluminum |
Manufacturer ID | 527682 |
Specifications may be subject to change without notice