Product Model
nebu-m12g5-e-10-q8n-m12g5

Selling Points
- 1ATEX Zone 2 Certified: Ensures safe operation in hazardous environments.
- 2Oil-Resistant: Withstands exposure to oils and chemicals.
- 3Suitable for Energy Chains: Designed for use in demanding mechanical environments.
- 4High Surge Resistance: 1.5 kV surge voltage strength for reliable electrical connections.
- 5Durable Construction: 5 x 1 mm² conductor cross-section and IP65/68/69K protection.
Technical Specifications
Detailed engineering parameters based on manufacturer documentation
Parameter | Value | Parameter | Value |
---|---|---|---|
Conforms to standard | EN 61076-2-101 | Explosion prevention and protection | Observe the information on the certificate Zone 2 (ATEX) Zone 22 (ATEX) |
Cable designation | Without label holder | Product weight | 835g |
Electrical connection 1, function | Field device end | Electrical connection 1, design | Round |
Electrical connection 1, connection type | Socket | Electrical connection 1, cable outlet | Straight |
Electrical connection 1, connection technology | M12x1 A-coded as per EN 61076-2-101 | Electrical connection 1, number of pins/wires | 5 |
Electrical connection 1, occupied pins/wires | 5 | Electrical connection 1, type of mounting | Screw-type lock |
Electrical connection for input 1, connection pattern | 00995384 | Electrical connection 2, function | Control side |
Electrical connection 2, design | Round | Electrical connection 2, connection type | Plug |
Electrical connection 2, cable outlet | Straight | Electrical connection 2, connection technology | M12x1 A-coded as per EN 61076-2-101 |
Electrical connection 2, number of pins/wires | 5 | Electrical connection 2, occupied pins/wires | 5 |
Electrical connection 2, type of mounting | Screw-type lock | Electrical connection 2, connection pattern | 00995383 |
DC operating voltage range | 0V 60V | Operating voltage range AC | 0V 60V |
Current rating at 40° C | 4A | Surge resistance | 1.5kV |
Cable length | 10m | Cable characteristic | Suitable for energy chains |
Connector cable test conditions | Flexural strength: as per Festo standard Test conditions on request Energy chain > 5 million cycles, bending radius 75 mm | Bending radius, fixed cable installation | 21mm |
Bending radius, flexible cable installation | 71mm | Cable diameter | 7mm |
Cable diameter tolerance | ± 0.1 mm | Cable design | 5 x 1 mm2 |
Nominal conductor cross section | 1mm2 | Degree of protection | IP65 IP68 IP69K |
Note on degree of protection | In mounted state | Special features | Oil-resistant |
Ambient temperature | -25°C 80°C | Ambient temperature with flexible cable installation | -5°C 80°C |
CE marking (see declaration of conformity) | As per EU low voltage directive As per EU RoHS directive | UKCA marking (see declaration of conformity) | To UK RoHS instructions To UK instructions for electrical equipment |
LABS (PWIS) conformity | VDMA24364-B2-L | Note on materials | RoHS-compliant Halogen-free Free of phosphoric acid ester |
Contamination level | 3 | Corrosion resistance class (CRC) | 2 - Moderate corrosion stress |
Material of cable sheath | TPE-U(PUR) | Color cable sheath | Gray |
Housing material | TPE-U(PUR) | Housing colour | Black |
Material of screw-type lock | Brass, nickel-plated | Seals material | NBR |
Material of pin contacts | Copper alloy, gold-plated | Insulating sheath material | PP |
Manufacturer ID | 574323 |
Specifications may be subject to change without notice