Festo pe-1/8

Selling Points

  • 1The Festo PE-1/8 pressure converter offers precise relative pressure measurement, ensuring accurate readings in pneumatic/electric applications.
  • 2Conforms to the standard EN 60947-5-1 and CE marked for compliance with EU and UK low voltage directives, ensuring safety and reliability.
  • 3Operates within a pressure range of 0 to 8 bar, making it suitable for various industrial applications.
  • 4Built with a die-cast aluminum housing reinforced with PA and steel, providing robustness and longevity.
  • 5Available with a G1/8 pneumatic connection and can be mounted on a 2N mounting frame or through-hole, offering flexibility in installation.
Product Details
pe-1/8
Festo

Technical Specifications

Detailed engineering parameters based on manufacturer documentation

ParameterValueParameterValue
Conforms to standard
EN 60947-5-1
Symbol
00991470
Certification
CCC
CE marking (see declaration of conformity)
As per EU low voltage directive
UKCA marking (see declaration of conformity)
To UK instructions for electrical equipment
Measured variable
Relative pressure
Method of measurement
Pneumatic/electric pressure transducer
Operating pressure
0.8bar 10bar
Operating medium
Compressed air as per ISO 8573-1:2010 [7:4:4]
Information on operating and pilot media
Operation with oil lubrication possible
Ambient temperature
-10°C 60°C
Switching output
Contact-based
Switching function
Threshold value with fixed hysteresis
Switching element function
Changeover switch
Max. switch-on point
0.8bar
Min. switch-off point
0.2bar
Max. switching output voltage AC
250V
Max. switching output voltage DC
250V
Utilization category for inductive load
AC-14 DC-13
Utilization category for ohmic load
AC-12 DC-12
Electrical connection
4-wire Cable
Electrical connection 1, connection type
Cable
Electrical connection 1, connection technology
Open end
Cable length
1m
Material of cable sheath
PVC
Type of mounting
With through-hole
Mounting position
Any
Pneumatic connection
G1/8
Product weight
225g
Housing material
Aluminum, anodized Die-cast zinc
Diaphragm material
Chloroprene rubber
Setting options
Permanently set
Degree of protection
IP65
Insulation voltage
2000V
LABS (PWIS) conformity
VDMA24364-B1/B2-L
Contamination level
3
Manufacturer ID
3344

Specifications may be subject to change without notice