Festo spte-b2r-pc10-b-2.5k

Selling Points

  • 1±3% FS accuracy ensures precise pressure measurements.
  • 2Utilizes a piezoresistive pressure sensor for reliable performance.
  • 3Meets RCM, c UL us, CE, and RoHS directives for global use.
  • 4Measures relative pressure from -0.1 MPa to 0.1 MPa (1 bar to 1 bar).
  • 5Lightweight at 35g with a 10mm cartridge pneumatic connection.
Product Details
spte-b2r-pc10-b-2.5k
Festo

Technical Specifications

Detailed engineering parameters based on manufacturer documentation

ParameterValueParameterValue
Symbol
00992257
Certification
RCM compliance mark c UL us - Recognized (OL)
CE marking (see declaration of conformity)
As per EU EMC directive As per EU RoHS directive
UKCA marking (see declaration of conformity)
To UK instructions for EMC To UK RoHS instructions
Certificate issuing authority
UL E322346
Note on materials
RoHS-compliant
Measured variable
Relative pressure
Method of measurement
Piezoresistive pressure sensor
Pressure measuring range initial value
-14.5psi
Pressure measuring range end value
14.5psi
Overload pressure
72.5psi
Operating medium
Compressed air as per ISO 8573-1:2010 [7:4:4]
Information on operating and pilot media
Operation with oil lubrication possible
Temperature of medium
0°C 50°C
Ambient temperature
0°C 50°C
Accuracy in ± % FS
3%FS
Repetition accuracy in ± %FS
0.3%FS
Temperature co-efficient in ± %FS/K
0.05%FS/K
Analog output
1 - 5 V
Rise time
1ms
Min. load resistance of voltage output
15kOhm
Short-circuit protection
For all electrical connections
DC operating voltage range
10V 30V
Reverse polarity protection
for all electrical connections
Electrical connection
3-wire Cable Open end
Cable length
2.5m
Type of mounting
Pin-type conneciton
Mounting position
Any
Pneumatic connection
Cartridge 10 mm
Product weight
35g
Housing material
PA-reinforced
Sealing ring material
FPM NBR
Degree of protection
IP40
Corrosion resistance class (CRC)
2 - Moderate corrosion stress
LABS (PWIS) conformity
VDMA24364-B2-L
Suitability for the production of Li-ion batteries
Metals with more than 1% by mass of copper, zinc or nickel are excluded from use.The exceptions are nickel in steel, chemically nickel-plated surfaces, circuit boards, cables, electrical plug connectors and coils
Cleanroom class
Class 4 according to ISO 14644-1
Manufacturer ID
8025977

Specifications may be subject to change without notice