Festo spte-p10r-s6-v-2.5k

Selling Points

  • 1High Accuracy: 0.3% FS repetition accuracy ensures precise pressure measurements.
  • 2Reliable Performance: Designed for long-term operation in environments up to 50°C.
  • 3Compressed Air Compatible: Meets ISO 8573-1:2010 standards for compressed air quality.
  • 4Robust Construction: Made from PA-reinforced housing with IP40 protection rating.
  • 5Easy Integration: Compatible with DC operating voltage range of 18-30 V, making it versatile for various applications.
Product Details
spte-p10r-s6-v-2.5k
Festo

Technical Specifications

Detailed engineering parameters based on manufacturer documentation

ParameterValueParameterValue
Symbol
00992257
Certification
RCM compliance mark c UL us - Recognized (OL)
CE marking (see declaration of conformity)
As per EU EMC directive As per EU RoHS directive
UKCA marking (see declaration of conformity)
To UK instructions for EMC To UK RoHS instructions
Certificate issuing authority
UL E322346
Note on materials
RoHS-compliant
Measured variable
Relative pressure
Method of measurement
Piezoresistive pressure sensor
Pressure measuring range initial value
0psi
Pressure measuring range end value
145psi
Overload pressure
217.5psi
Operating medium
Compressed air as per ISO 8573-1:2010 [7:4:4]
Information on operating and pilot media
Operation with oil lubrication possible
Temperature of medium
0°C 50°C
Ambient temperature
0°C 50°C
Accuracy in ± % FS
3%FS
Repetition accuracy in ± %FS
0.3%FS
Temperature co-efficient in ± %FS/K
0.05%FS/K
Analog output
0 - 10 V
Rise time
1ms
Min. load resistance of voltage output
15kOhm
Short-circuit protection
For all electrical connections
DC operating voltage range
18V 30V
Reverse polarity protection
for all electrical connections
Electrical connection
3-wire Cable Open end
Cable length
2.5m
Type of mounting
Plug-in
Mounting position
Any
Pneumatic connection
Push-in sleeve QS-6
Product weight
35g
Housing material
PA-reinforced
Sealing ring material
FPM
Degree of protection
IP40
Corrosion resistance class (CRC)
2 - Moderate corrosion stress
LABS (PWIS) conformity
VDMA24364-B2-L
Suitability for the production of Li-ion batteries
Metals with more than 1% by mass of copper, zinc or nickel are excluded from use.The exceptions are nickel in steel, chemically nickel-plated surfaces, circuit boards, cables, electrical plug connectors and coils
Cleanroom class
Class 4 according to ISO 14644-1
Manufacturer ID
571485

Specifications may be subject to change without notice