Product Model
vacf-a-a1-7a

Selling Points
- 1High Performance: 48 V AC, 50/60 Hz, pick-up power 2.5 VA, holding power 1.7 VA.
- 2Reliable Operation: 100% duty cycle, H insulation class, and ±10% permissible voltage fluctuation.
- 3Versatile Mounting: Any assembly position, with knurled nut for secure mounting.
- 4Maritime Compliance: Certified by DNVGL-TAA000011J, suitable for maritime applications.
- 5Compliance Standards: RoHS compliant, IP65 protection class, and CE certificate for EU low voltage directive.
Technical Specifications
Detailed engineering parameters based on manufacturer documentation
Parameter | Value | Parameter | Value |
---|---|---|---|
Mounting position | Any | Conforms to standard | IEC 61010-1 |
Duty cycle | 100% | Insulation class | H |
Coil characteristics | 48 V AC: 50/60 Hz, initial power 2.5 VA, holding power 1.7 VA | Permissible voltage fluctuations | +/- 10 % |
Certification | c UL us - Recognized (OL) | Maritime classification | See certificate |
Certificate issuing authority | DNVGL-TAA000011J UL MH18122 | Restricted ambient and media temperature | -20 - 50 °C |
Corrosion resistance class (CRC) | 2 - Moderate corrosion stress | LABS (PWIS) conformity | VDMA24364-B1/B2-L |
Temperature of medium | -20°C 50°C | Degree of protection | IP65 |
Ambient temperature | -20°C 60°C | Product weight | 82.3g |
Electrical connection | Form A as per EN 175301-803 | Type of mounting | With knurled nut |
Note on materials | RoHS-compliant | Housing material | PA Steel |
Solenoid coil material | Copper Steel Thermoplastic | Material of winding | Copper |
Manufacturer ID | 8030825 |
Specifications may be subject to change without notice