Product Model

vppm-8f-l-1-f-0l6h-lk-s1

In Stock
Last updated: 2025/4/18
Festo vppm-8f-l-1-f-0l6h-lk-s1

Selling Points

  • 1Regulates pressure accurately within 0.006 MPa to 0.6 MPa.
  • 2Ensures reliable and long-lasting operation with soft sealing.
  • 3Supports direct connection to higher-order IO-Link/I-Port masters for seamless communication.
  • 4Easy to operate with electrical actuation for precise control.
  • 5Meets IP65 protection standards and operates in temperatures from 0°C to 60°C.
Product Details
vppm-8f-l-1-f-0l6h-lk-s1
Festo

Technical Specifications

Detailed engineering parameters based on manufacturer documentation

ParameterValueParameterValue
Nominal width pressurization
8mm
Exhaust nominal width
7mm
Actuation type
Electrical
Sealing principle
Soft
Mounting position
Any
Structural design
Pilot-controlled diaphragm regulator
Short-circuit protection
For all electrical connections
Safety instructions
VPPM safety position: if the supply cable breaks, the outlet pressure is maintained in uncontrolled form.
Symbol
00995303
Reverse polarity protection
for all electrical connections
Reset method
Mechanical spring
Type of control
Pilot-controlled
Valve function
3-way proportional pressure control valve
Display type
LED
Pressure regulation range MPa
0.006MPa 0.6MPa
Pressure regulation range
0.06bar 6bar
Inlet pressure 1
0bar 8bar
Inlet pressure 1 MPa
0MPa 0.8MPa
Max. pressure hysteresis
0.03bar
Standard nominal flow rate
1050l/min
DC operating voltage range
18V 30V
Max. current consumption
300mA
Duty cycle
100%
Max. electrical power consumption
7W
Protocol
I-Port IO-Link?
Residual ripple
10 %
Operating medium
Compressed air as per ISO 8573-1:2010 [7:4:4] Inert gas
Information on operating and pilot media
Operation with oil lubrication not possible
Certification
RCM compliance mark c UL us - Listed (OL)
KC characters
KC EMC
CE marking (see declaration of conformity)
As per EU EMC directive As per EU RoHS directive
UKCA marking (see declaration of conformity)
To UK instructions for EMC To UK RoHS instructions
Certificate issuing authority
UL E322346
Corrosion resistance class (CRC)
2 - Moderate corrosion stress
LABS (PWIS) conformity
VDMA24364-B1/B2-L
Temperature of medium
10°C 50°C
Degree of protection
IP65
Ambient temperature
0°C 60°C
Product weight
560g
Linearity
1%FS
Hysteresis
0.5%FS
Reproducibility
0.5%FS
Overall accuracy
1.25 %FS
Temperature coefficient
0.04%/K
Repetition accuracy FS
0.5%
IO-Link?, protocol version
Device V 1.1
IO-Link?, communication mode
COM1 (4.8 kBd), COM2 (38.4 kBd), COM3 (230.4 kBd)
IO-Link?, port class
A
IO-Link?, process data width OUT
2 Byte
IO-Link?, process data width IN
2 Byte
IO-Link?, minimum cycle time
0.5 ms
Type of mounting
Optionally: With through-hole With accessories
Pneumatic connection 1
Sub-base
Pneumatic connection 2
Sub-base
Pneumatic connection 3
Sub-base
Note on materials
RoHS-compliant
Housing material
Wrought aluminum alloy Anodized
Manufacturer ID
8031111

Specifications may be subject to change without notice