Product Model
vuvg-l10-t32c-azt-m7-1p3

Selling Points
- 1High-Performance Air Control: Precise control of compressed air with a standard nominal flow rate of 170 l/min.
- 2Electrical Actuation: Easy to operate with 24V DC electrical actuation for reliable valve function.
- 3Compact Design: Compact 10 mm valve size for space-efficient installations.
- 4Robust Construction: Built with a piston gate valve design and soft sealing principle for durability.
- 5Versatile Mounting Options: Suitable for any mounting position with optional manual override and detenting options.
Technical Specifications
Detailed engineering parameters based on manufacturer documentation
Parameter | Value | Parameter | Value |
---|---|---|---|
Valve function | 2x3/2, closed, monostable | Actuation type | Electrical |
Valve size | 10mm | Standard nominal flow rate | 170l/min |
Pneumatic working port | M7 | Operating voltage | 24V DC |
Operating pressure | 1.5bar 10bar | Structural design | Piston gate valve |
Reset method | Pneumatic spring | Certification | RCM compliance mark c UL us - Recognized (OL) |
Degree of protection | IP40 IP65 With plug socket | Nominal width | 2.7mm |
Exhaust air function | With flow control option | Sealing principle | Soft |
Mounting position | Any | Manual override | Detenting Non-detenting Covered |
Type of control | Pilot-controlled | Pilot air supply port | External |
Symbol | 00992912 | Lap | Overlap |
Pilot pressure MPa | 0.15MPa 0.8MPa | Pilot pressure | 1.5bar 8bar |
Suitability for vacuum | no | Switching time off | 15ms |
On switching time | 6ms | Duty cycle | 100% |
Max. positive test pulse with 0 signal | 700μs | Max. negative test pulse on 1 signal | 900μs |
Coil characteristics | 24 V DC: 1.0 W 24 V DC: low-current phase 0.3 W, high-current phase 1.0 W | Permissible voltage fluctuations | +/- 10 % |
Operating medium | Compressed air as per ISO 8573-1:2010 [7:4:4] | Information on operating and pilot media | Operation with oil lubrication possible (required for further use) |
Vibration resistance | Transport application test with severity level 2 as per FN 942017-4 and EN 60068-2-6 | Restricted ambient and media temperature | -5 - 50 °C Without holding power reduction |
Shock resistance | Shock test with severity level 2 as per FN 942017-5 and EN 60068-2-27 | Corrosion resistance class (CRC) | 2 - Moderate corrosion stress |
LABS (PWIS) conformity | VDMA24364-B1/B2-L | Cleanroom class | Class 5 according to ISO 14644-1 |
Temperature of medium | -5°C 60°C | Pilot medium | Compressed air as per ISO 8573-1:2010 [7:4:4] |
Ambient temperature | -5°C 60°C | Product weight | 55g |
Electrical connection | Via electrical sub-base | Type of mounting | Optionally: On terminal strip With through-hole |
Pilot air port 12/14 | M3 | Pneumatic connection 1 | M7 |
Pneumatic connection 2 | M7 | Pneumatic connection 3 | M7 |
Pneumatic connection 4 | M7 | Pneumatic connection 5 | M7 |
Note on materials | RoHS-compliant | Seals material | HNBR NBR |
Housing material | Wrought aluminum alloy | Manufacturer ID | 566479 |
Specifications may be subject to change without notice