Product Model
vuvg-l10-t32u-mt-m7-1r8l

Selling Points
- 1High-Performance Air Control: Precise control of air flow with a 2x3/2-way valve function.
- 2Electrical Actuation: Easy operation with 24VDC voltage for reliable actuation.
- 310mm Port Size: Compact design with a 10mm port size for efficient media flow.
- 4Mechanical Spring Reset: Reliable reset method using a mechanical spring for consistent performance.
- 5IP65 Protection: Durable construction with IP65 degree of protection against dust and water.
Technical Specifications
Detailed engineering parameters based on manufacturer documentation
Parameter | Value | Parameter | Value |
---|---|---|---|
Valve function | 2x3/2, open, monostable | Actuation type | Electrical |
Valve size | 10mm | Standard nominal flow rate | 155l/min |
Pneumatic working port | M7 | Operating voltage | 24V DC |
Operating pressure | 2.5bar 8bar | Structural design | Piston gate valve |
Reset method | Mechanical spring | Certification | RCM compliance mark c UL us - Recognized (OL) |
Degree of protection | IP65 With plug socket | Nominal width | 1.9mm |
Exhaust air function | With flow control option | Sealing principle | Soft |
Mounting position | Any | Manual override | Detenting Non-detenting Covered |
Type of control | Pilot-controlled | Pilot air supply port | Internal |
Symbol | 00995244 | Lap | Overlap |
Pilot pressure MPa | 0.2MPa 0.8MPa | Pilot pressure | 2bar 8bar |
Suitability for vacuum | no | Switching time off | 11ms |
On switching time | 8ms | Duty cycle | 100% |
Max. positive test pulse with 0 signal | 700μs | Max. negative test pulse on 1 signal | 900μs |
Coil characteristics | 24 V DC: 1.0 W | Permissible voltage fluctuations | +/- 10 % |
Operating medium | Compressed air as per ISO 8573-1:2010 [7:4:4] | Information on operating and pilot media | Operation with oil lubrication possible (required for further use) |
Vibration resistance | Transport application test with severity level 2 as per FN 942017-4 and EN 60068-2-6 | Restricted ambient and media temperature | -5 - 50 °C Without holding power reduction |
Shock resistance | Shock test with severity level 2 as per FN 942017-5 and EN 60068-2-27 | Corrosion resistance class (CRC) | 2 - Moderate corrosion stress |
LABS (PWIS) conformity | VDMA24364-B1/B2-L | Cleanroom class | Class 5 according to ISO 14644-1 |
Temperature of medium | -5°C 60°C | Ambient temperature | -5°C 60°C |
Product weight | 54g | Electrical connection | Via electrical sub-base |
Type of mounting | Optionally: On terminal strip With through-hole | Pneumatic connection 1 | M7 |
Pneumatic connection 2 | M7 | Pneumatic connection 4 | M7 |
Pneumatic connection 5 | M7 | Note on materials | RoHS-compliant |
Seals material | HNBR NBR | Housing material | Wrought aluminum alloy |
Manufacturer ID | 8031481 |
Specifications may be subject to change without notice