Festo vuvs-25

Selling Points

  • 1High flow rate up to 1300 l/min.
  • 2Durable design with piston gate valve and poppet seat.
  • 3Versatile mounting options including manifold rail and through-hole.
  • 4Compatible with various operating voltages (110V AC, 120V AC, 12V DC, etc.).
  • 5Meets ATEX and CE marking standards for explosion protection and safety.
Product Details
vuvs-25
Festo

Technical Specifications

Detailed engineering parameters based on manufacturer documentation

ParameterValueParameterValue
Valve function
2x3/2, closed, monostable 2x3/2, open, monostable 2x3/2, open/closed, monostable 3/2, closed, monostable 3/2, open, monostable 5/2, bistable 5/2, monostable 5/3, pressurized 5/3, exhausted 5/3, closed
Actuation type
Electrical
Valve size
26.5mm
Standard nominal flow rate
1000l/min 1300l/min
Pneumatic working port
G1/4 1/4 NPT QS-6 QS-8 QS-10 QS-1/4 QS-5/16 QS-3/8
Operating voltage
110V AC 120V AC 12V DC 230V AC 240V AC 24V AC 24V DC Via solenoid coil, to be ordered separately
Operating pressure
-0.9bar 10bar
Structural design
Piston gate valve Plate seat
Reset method
Mechanical spring Pneumatic spring
Certification
c UL us - Recognized (OL)
Maritime classification
See certificate
CE marking (see declaration of conformity)
as per EU explosion protection directive (ATEX) As per EU low voltage directive
Explosion protection certification outside the EU
Class I, Div. 1 (US) Class II, Div. 1 (US) Class III, Div. 1 (US) EPL Db (IEC-EX) EPL Dc (GB) EPL Ga (IEC-EX) EPL Gb (IEC-EX) EPL Gc (GB)
UKCA marking (see declaration of conformity)
acc. to UK EX instructions To UK instructions for electrical equipment
Certificate issuing authority
DNVGL-TAA000011J
ATEX category gas
II 2G II 3G
ATEX category for dust
II 2D II 3D
Type of ignition protection for gas
AEx m II T4 Ex ec IIC T4 Gc X Ex ia IIC T6, T4 Gb Ex m II T4 Ex mb IIC T6 Gb Ex nA IIC T5/T4 X Gc
Type of (ignition) protection for dust
Ex mb tb IIIC T80°C Db Ex tb IIIC T80°C, T130°C Db IP65 Ex tc IIIC T115°C Dc X Ex tc IIIC T95°C/T105°C X Dc
Explosive ambient temperature
-10°C <= Ta <= +60°C -20°C <= Ta <= +50°C -20°C <= Ta <= +60°C T4, T130°C: -40°C <= Ta <= +85°C T6, T80°C: -40°C <= Ta <= +50°C
Degree of protection
IP65 IP67 With plug socket as per IEC 60529
Exhaust air function
With flow control option
Sealing principle
Soft
Mounting position
Any
Type of control
Pilot-controlled
Explosion prevention and protection
Class I, Div. 1 (US) Class II, Div. 1 (US) Class III, Div. 1 (US) Observe the information on the certificate Zone 0 (IEC-EX) Zone 1 (ATEX) Zone 1 (IEC-EX) Zone 2 (ATEX) Zone 2 (UKEX) Zone 21 (ATEX) Zone 21 (IEC-EX) Zone 22 (ATEX) Zone 22 (UKEX)
Operating medium
Compressed air as per ISO 8573-1:2010 [7:4:4]
Information on operating and pilot media
Operation with oil lubrication possible (required for further use)
Corrosion resistance class (CRC)
2 - Moderate corrosion stress
LABS (PWIS) conformity
VDMA24364-B1/B2-L
Cleanroom class
Class 6 according to ISO 14644-1
Pilot medium
Compressed air as per ISO 8573-1:2010 [7:4:4]
Type of mounting
Optionally: On terminal strip With through-hole
Venting hole connection
Not ducted
Note on materials
RoHS-compliant
Housing material
Die-cast aluminum Painted
Material of screws
Steel, galvanized
Manufacturer ID
8022014

Specifications may be subject to change without notice