Product Model

ELR H5-IES-SC-230AC/500AC-2

In Stock
Last updated: 2025/4/17
Phoenix Contact ELR H5-IES-SC-230AC/500AC-2

Selling Points

  • 1Hybrid Motor Starter for Reversing 3~ AC Motors: Efficiently handles motors up to 500 V AC with adjustable overload shutdown.
  • 2SIL 3/PL e Safety Level: Meets high safety standards for SIL 3 and ISO 13849: PL e.
  • 3Space-Saving Design: Compact 22.5 mm wide, ideal for space-constrained applications.
  • 4Adjustable Current for Bimetal Function: Allows for precise control over motor operation.
  • 5Low-Wear Switching and Long Service Life: Reduces wear and tear, ensuring extended motor starter lifespan.
Product Details
ELR H5-IES-SC-230AC/500AC-2
Phoenix Contact

Technical Specifications

Detailed engineering parameters based on manufacturer documentation

ParameterValueParameterValue
Product type
Hybrid motor starters
Product family
CONTACTRON
Operating mode
100% operating factor
Article revision
09
Number of phases
3
Motor starter type
Reversing starter
Switching frequency
≤ 2 Hz (Load-dependent)
Maximum power dissipation for nominal condition
2.2 W
Switching frequency
≤ 2 Hz (Load-dependent)
Maximum power dissipation
4.7 W
Minimum power dissipation
2.6 W
Coordination type
1
Rated control circuit supply voltage U
230 V AC
Control supply voltage range
85 V AC ... 253 V AC
Rated control supply current I
4 mA
Mains frequency
50/60 Hz
Protective circuit
Surge protection
Rated insulation voltage
500 V
Rated surge voltage
4 kV
Overvoltage category
III
Degree of pollution
2
Insulation characteristics between the control input and control supply voltage, and auxiliary circuit to the main circuit
Safe isolation (IEC 60947-1/EN 50178) at operating voltage ≤ 300 V AC Basic insulation (IEC 60947-1) at operating voltage 300 V AC ... 500 V AC Safe isolation (EN 50178) at operating voltage 300 ... 500 V AC
Isolation characteristics between the control input and control supply voltage to auxiliary circuit
Safe isolation (IEC 60947-1) in the auxiliary circuit ≤ 300 V AC Safe isolation (EN 50178) in the auxiliary circuit ≤ 300 V AC
Input name
Control input right/left
Rated actuating voltage U
230 V AC
Triggering voltage range
85 V AC ... 253 V AC
Rated actuating current I
7 mA (Input type 1)
Mains frequency
50 Hz 60 Hz 50/60 Hz
Switching threshold
44 V AC (“0” signal) 85 V AC (“1” signal)
Switching level
< 5 V AC (For EMERGENCY STOP)
Typical turn-off time
< 70 ms
Rated operating voltage U
500 V AC
Operating voltage range
42 V AC ... 550 V AC
Rated operating current I
2.4 A (AC-51) 2.4 A (AC-53a)
Mains frequency
50/60 Hz
Load current range
180 mA ... 2.4 A (see to derating)
Trigger characteristic in acc. with IEC 60947-4-2
Class 10A
Cooling time
20 min (for auto reset)
Leakage current
0 mA
Protective circuit
Surge protection
Note
Confirmation: floating change-over contact, signal contact
Contact switching type
1 changeover contact
Switching capacity in accordance with IEC 60947-5-1
3 A (230 V, AC15) 2 A (24 V, DC13)
Connection method
Screw connection
Stripping length
8 mm
Screw thread
M3
Conductor cross section rigid
0.2 mm² ... 2.5 mm²
Conductor cross section flexible
0.2 mm² ... 2.5 mm²
Conductor cross section AWG
24 ... 14
Tightening torque
0.5 Nm ... 0.6 Nm 5 lb
Connection method
Screw connection
Stripping length
8 mm
Screw thread
M3
Conductor cross section rigid
0.2 mm² ... 2.5 mm²
Conductor cross section flexible
0.2 mm² ... 2.5 mm²
Conductor cross section AWG
24 ... 14
Tightening torque
0.5 Nm ... 0.6 Nm 5 lb
Status display
LED (yellow)
Operating voltage display
Green LED
Error indication
Red LED
Width
22.5 mm
Height
107 mm
Depth
114 mm
Flammability rating according to UL 94
V0 (Housing)
Degree of protection
IP20
Ambient temperature (operation)
-25 °C ... 70 °C (observe derating)
Ambient temperature (storage/transport)
-40 °C ... 80 °C
Altitude
≤ 2000 m
Certificate
UKCA-compliant
Identification
 II (2) G [Ex e] [Ex d] [Ex px]  II (2) D [Ex t] [Ex p]
Certificate
PTB 07 ATEX 3145
Certificate
NLDX.E228652
Identification
≤ 3
Note
Safe shutdown
Identification
2
Note
Motor protection
Identification
≤ e
Note
Safe shutdown
Identification
≤ 3
Note
Safe shutdown
SCCR
100 kA (500 V AC (fuse: 30 A class CC/30 A class J (high fault))) 5 kA (500 V AC (fuse: 20 A RK5 (standard fault)))
FLA
2.4 A (500 V AC)
Group installation
20 A (class RK5, SCCR 5kA, #24 - 14 AWG max. solid and stranded) 30 A (class CC or J, SCCR 100kA, #24 - 14 AWG max, solid and stranded)
Category code
NLDX
Standards/regulations
IEC 60947-1 IEC 60947-4-2 IEC 61508 ISO 13849
Mounting type
DIN rail mounting
Assembly note
alignable, for spacing see derating
Mounting position
vertical (horizontal DIN rail, motor output below)