Product Model

ELR HDC-PT-24/650/55-IOL

In Stock
Last updated: 2025/4/17
Phoenix Contact ELR HDC-PT-24/650/55-IOL

Selling Points

  • 1High-efficiency design for reduced power consumption.
  • 2Compact size with robust build quality.
  • 3Wide input voltage range for versatile use.
  • 4Advanced thermal management for extended lifespan.
  • 5Compliant with international safety standards.
Product Details
ELR HDC-PT-24/650/55-IOL
Phoenix Contact

Technical Specifications

Detailed engineering parameters based on manufacturer documentation

ParameterValueParameterValue
Product type
Circuit breakers
Product family
CONTACTRON
Article revision
02
Overvoltage category
III
Pollution degree
2
Selectivity category
A (IEC/EN 60947-2)
Rated insulation voltage
440 V DC
Rated impulse withstand voltage
6 kV
Rated service short-circuit breaking capacity I
100 kA (650 V DC)
Rated ultimate short-circuit breaking capacity I
100 kA (650 V DC)
Precharging
1 s (1 mF) ≤ 15 A
Maximum power dissipation for nominal condition
55 W
Measuring range
0 V ... 900 V ±2 %
Measuring range
-90 A ... 90 A ±2 %
Messbereich_Leistung
-75 kW ... 75 kW ±4 %
Rated control supply voltage U
24 V DC
Control supply voltage range U
19.2 V DC ... 26 V DC
Rated control supply current I
40 mA
Rated control supply current I
120 mA
Rated control supply current I
≤ 210 mA
Protective circuit
Surge protection Reverse polarity protection
Rated actuating voltage U
24 V DC
Triggering voltage range
-3 V DC ... 30 V DC
Switching threshold (0 signal)
9.6 V
Switching threshold (1 signal)
19.2 V
Actuating current I
5 mA
Switch-off time
< 5 ms
Switch-on time (without precharging)
400 ms
Output voltage (0 signal)
≤ 1 V
Output voltage (1 signal)
U
Output current
≤ 300 mA
Protective circuit
Short-circuit-proof
Number of positions
2
Operating voltage range
0 V DC ... 810 V DC
Rated voltage U
650 V DC
Rated operating voltage U
440 V DC
Rated operating voltage U
325 V DC (Conductor-PE) 650 V DC (Conductor-Conductor)
Rated current I
55 A (40 °C)
Current setting I
5 A ... 55 A
Current setting I
10 A ... 90 A
Tripping time t
can be parameterized
Tripping time t
0.2 s
Tripping current I
200 A
Switch-on delay
can be parameterized
Connection method
Push-in connection
Stripping length
8 mm
Conductor cross section rigid
0.2 mm² ... 1.5 mm²
Conductor cross section flexible
0.2 mm² ... 1.5 mm²
Conductor cross section AWG
24 ... 16
Connection method
Push-in connection
Stripping length
18 mm
Conductor cross section rigid
0.75 mm² ... 16 mm²
Conductor cross section flexible
0.75 mm² ... 16 mm²
Conductor cross section AWG
20 ... 6
Communication protocol
IO-Link
Specification
1.1.3
Transmission speed
230400 baud
Cycle time
2 ms
Amount of process data
12 Byte (Input data) 1 Byte (Output data)
Current consumption
10 mA
Width
84 mm
Height
203 mm
Depth
117 mm
Diameter
5.6 mm
Degree of protection
IP20
Ambient temperature (operation)
-20 °C ... 60 °C (non-condensing)
Ambient temperature (storage/transport)
-40 °C ... 70 °C
Altitude
≤ 2000 m
Impulse withstand voltage (StKr/Bus)
1.5 kV
Impulse withstand voltage (HStrKr/StKr)
8 kV
Impulse withstand voltage (HStrKr/Bus)
8 kV
Standards/regulations
IEC 60947-2
Mounting type
DIN rail mounting Direct mounting

Specifications may be subject to change without notice