Product Model
FLK 16/14/DV-IN/ 30

Selling Points
- 1High Operating Voltage: Supports up to 30 V AC and 60 V DC for versatile industrial use.
- 2Efficient Current Handling: Handles up to 1 A per path at 50°C, ensuring reliable signal transmission.
- 3Durable Construction: Made with semi-rigid PVC and tin-plated Cu litz wires for long-lasting performance.
- 4Flexible Installation: Suitable for both fixed and flexible installations, with a smallest bending radius of 58 mm.
- 5Compliant with Industry Standards: Meets IEC 60332-1-2 and VDE 0842, Part 332-1-2 for safety and flame resistance.
Technical Specifications
Detailed engineering parameters based on manufacturer documentation
Parameter | Value | Parameter | Value |
---|---|---|---|
Product type | System cable | Ambient temperature (operation) | -20 °C ... 50 °C |
Ambient temperature (storage/transport) | -20 °C ... 70 °C | Operating voltage (AC) | ≤ 50 V AC |
Operating voltage (DC) | ≤ 60 V DC | Current (Per path) | ≤ 1 A |
Suitable I/O card | VE4001S2T1B3
VE4001S2T2B3 | Cable length | 0.3 m |
Number of positions | 16 | Shielded | no |
Cable type | 16X0.14 [PVC] | Conductor type | Round cable set |
Conductor structure signal line | 7x 0.16 mm | AWG signal line | 26 |
Conductor cross section | 16x 0.14 mm² | Wire diameter incl. insulation | 1 mm ±0.03 mm |
External cable diameter | 6.80 mm ±0.4 mm | Outer sheath, material | Semi-rigid PVC |
External sheath, color | gray | Conductor material | Tin-plated Cu litz wires |
Cable resistance | ≤ 145 Ω/km (20 °C) | Insulation resistance | ≥ 20 MΩ*km (20 °C) |
Smallest bending radius, fixed installation | 58 mm | Smallest bending radius, movable installation | 108 mm |
Dynamic load capacity (bending) | Max. bending cycles: 5000 (at a radius of ≥ 15x outside diameter) | Halogen-free | no |
Flame resistance | IEC 60332-1-2 (raw cable)
VDE 0842, Part 332-1-2 (raw cable)
IEC 60332-3-22 (raw cable)
UL VW-1
CSA FT-1 | Resistance to oil | can withstand occasional splashes (raw cable) |
Connection method | IDC/FLK socket strip | Number of connections | 1 |
Number of positions | 14 | Pitch | 2.54 mm |
Connection method | IDC/FLK socket strip | Number of connections | 1 |
Number of positions | 16 | Pitch | 2.54 mm |
Notes on operation | For proper use, the specifications of the installation directive (see Downloads) must be observed. For applications or use with third-party products, the specifications, and the safety and warning instructions of the respective third-party manufacturer must also be met. |
Specifications may be subject to change without notice