Product Model
FLK 16/14/DV-IN/400

Selling Points
- 1Designed for Emerson Delta V Systems: Compatible with Emerson Delta V controllers for seamless integration.
- 2High Reliability: Built with tin-plated copper wires for long-lasting performance and resistance to corrosion.
- 3Flexible Installation: Operates between -10°C to 70°C, making it suitable for various installation conditions.
- 4Durable Construction: Semi-rigid PVC outer sheath ensures robustness and resistance to environmental factors.
- 5Compliant with Safety Standards: Meets UL VW-1 and CSA FT-1 flame resistance standards for safety assurance.
Technical Specifications
Detailed engineering parameters based on manufacturer documentation
Parameter | Value | Parameter | Value |
---|---|---|---|
Product type | System cable | Article revision | 03 |
Degree of protection | IP00 | Degree of protection (Installation location) | ≥ IP54 (Installation location) |
Ambient temperature (operation) | -40 °C ... 70 °C (fixed installation)
-10 °C ... 70 °C (flexible installation) | Ambient temperature (storage/transport) | -40 °C ... 80 °C |
Altitude | ≤ 2000 m | Operating voltage (AC) | ≤ 30 V AC |
Operating voltage (DC) | ≤ 60 V DC | Nominal operating mode | 100% operating factor |
Current (Per path, 50°C) | ≤ 1 A (Uncoiled, see derating) | Current (Per path, 70°C) | ≤ 0.6 A (Uncoiled, see derating) |
Suitable I/O card | VE4001S2T1B3
VE4001S2T2B3 | Cable length | 4 m |
Number of positions | 16 | Shielded | no |
Cable type | 16X0.14 [PVC] | Conductor type | Round cable set |
Conductor structure signal line | 7x 0.16 mm | AWG signal line | 26 |
Conductor cross section | 16x 0.14 mm² | Wire diameter incl. insulation | 1 mm ±0.03 mm |
External cable diameter | 6.80 mm ±0.4 mm | Outer sheath, material | Semi-rigid PVC |
External sheath, color | gray | Conductor material | Tin-plated Cu litz wires |
Cable resistance | ≤ 145 Ω/km (20 °C) | Insulation resistance | ≥ 20 MΩ*km (20 °C) |
Smallest bending radius, fixed installation | 58 mm | Smallest bending radius, movable installation | 108 mm |
Dynamic load capacity (bending) | Max. bending cycles: 5000 (at a radius of ≥ 15x outside diameter) | Halogen-free | no |
Flame resistance | IEC 60332-1-2 (raw cable)
VDE 0842, Part 332-1-2 (raw cable)
IEC 60332-3-22 (raw cable)
UL VW-1
CSA FT-1 | Resistance to oil | can withstand occasional splashes (raw cable) |
Cable type | Cable for one module | black | IDC/FLK16 (1) = IDC/FLK14 (1) |
brown | IDC/FLK16 (2) = IDC/FLK14 (9) | red | IDC/FLK16 (3) = IDC/FLK14 (2) |
orange | IDC/FLK16 (4) = IDC/FLK14 (9) | yellow | IDC/FLK16 (5) = IDC/FLK14 (3) |
green | IDC/FLK16 (6) = IDC/FLK14 (9) | blue | IDC/FLK16 (7) = IDC/FLK14 (4) |
violet | IDC/FLK16 (8) = IDC/FLK14 (11) | gray | IDC/FLK16 (9) = IDC/FLK14 (5) |
white | IDC/FLK16 (10) = IDC/FLK14 (11) | white-black | IDC/FLK16 (11) = IDC/FLK14 (6) |
white-brown | IDC/FLK16 (12) = IDC/FLK14 (11) | white-red | IDC/FLK16 (13) = IDC/FLK14 (7) |
white-orange | IDC/FLK16 (14) = IDC/FLK14 (13) | white-yellow | IDC/FLK16 (15) = IDC/FLK14 (8) |
white-green | IDC/FLK16 (16) = IDC/FLK14 (13) | Connection in acc. with standard | IEC 60603-13 (in compliance) |
Connection method | IDC/FLK socket strip | Number of connections | 1 |
Number of positions | 16 | Insertion/withdrawal cycles | > 50 |
Pitch | 2.54 mm | Connection in acc. with standard | IEC 60603-13 (in compliance) |
Connection method | IDC/FLK socket strip | Number of connections | 1 |
Number of positions | 14 | Insertion/withdrawal cycles | > 50 |
Pitch | 2.54 mm | Notes on operation | For proper use, the specifications of the installation directive (see Downloads) must be observed. For applications or use with third-party products, the specifications, and the safety and warning instructions of the respective third-party manufacturer must also be met. |
Specifications may be subject to change without notice