Product Model
FLK 16/EZ-DR/ 100/KONFEK/S

Selling Points
- 1High-Quality Shielded Design: Ensures reliable signal transmission with a tinned copper-braided shield.
- 2Efficient Connection: Assembled with two 16-position socket strips at both ends for easy and secure connections.
- 3Industrial-Grade Construction: Built with 7 Litz wires and a conductor cross section of 0.14 mm² (AWG 26) for robust performance.
- 4Flexible Length Options: Available in various fixed lengths from 0.5 m to 10 m to suit different application needs.
- 5Compliant with Industry Standards: Meets IEC 60603-1/DIN 41651 and UL/CUL approvals for safety and reliability.
Technical Specifications
Detailed engineering parameters based on manufacturer documentation
Parameter | Value | Parameter | Value |
---|---|---|---|
Product type | System cable | Article revision | 03 |
Degree of protection | IP00 | Degree of protection (Installation location) | ≥ IP54 (Installation location) |
Ambient temperature (operation) | -40 °C ... 70 °C (fixed installation)
-10 °C ... 70 °C (flexible installation) | Ambient temperature (storage/transport) | -40 °C ... 80 °C |
Altitude | ≤ 2000 m | Operating voltage (AC) | ≤ 30 V AC |
Operating voltage (DC) | ≤ 60 V DC | Nominal operating mode | 100% operating factor |
Current (Per path, 50°C) | ≤ 1 A (Uncoiled, see derating) | Current (Per path, 70°C) | ≤ 0.6 A (Uncoiled, see derating) |
Cable length | 1 m | Number of positions | 16 |
Shielded | yes | Cable type | 16X0.14 [PVC] |
Conductor type | Assembled shielded round cable | Conductor structure signal line | 7x 0.16 mm |
AWG signal line | 26 | Conductor cross section | 16x 0.14 mm² |
Wire diameter incl. insulation | 1 mm ±0.03 mm | External cable diameter | 7.00 mm ±0.4 mm |
Outer sheath, material | Semi-rigid PVC | External sheath, color | gray |
Conductor material | Tin-plated Cu litz wires | Cable resistance | ≤ 145 Ω/km (20 °C) |
Insulation resistance | ≥ 20 MΩ*km (20 °C) | Smallest bending radius, fixed installation | 74 mm |
Smallest bending radius, movable installation | 133 mm | Dynamic load capacity (bending) | Max. bending cycles: 5000 (at a radius of ≥ 15x outside diameter) |
Halogen-free | no | Flame resistance | IEC 60332-1-2 (raw cable)
VDE 0842, Part 332-1-2 (raw cable)
IEC 60332-3-22 (raw cable)
UL VW-1
CSA FT-1 |
Resistance to oil | can withstand occasional splashes (raw cable) | Cable type | Cable for one module |
Connection in acc. with standard | IEC 60603-13 (in compliance) | Connection method | IDC/FLK socket strip |
Number of connections | 1 | Number of positions | 16 |
Insertion/withdrawal cycles | > 50 | Pitch | 2.54 mm |
Connection in acc. with standard | IEC 60603-13 (in compliance) | Connection method | IDC/FLK socket strip |
Number of connections | 1 | Number of positions | 16 |
Note | The braided shield is routed to a separate cable end.
The separate cable end is approximately 0.5 m long (H05V-K 1 mm², black) | Insertion/withdrawal cycles | > 50 |
Pitch | 2.54 mm | Notes on operation | For proper use, the specifications of the installation directive (see Downloads) must be observed. For applications or use with third-party products, the specifications, and the safety and warning instructions of the respective third-party manufacturer must also be met. |
Specifications may be subject to change without notice