Product Model
FLK 24/EZ-DR/1500/KONFEK/S

Selling Points
- 1The FLK 24/EZ-DR/1500/KONFEK/S features a braided shield for superior electromagnetic interference (EMI) protection.
- 2Made with semi-rigid PVC and tin-plated Cu litz wires, this cable ensures long-lasting performance in harsh environments.
- 3Compatible with both fixed and flexible installations, operating within a wide ambient temperature range of -40°C to 70°C.
- 4Supports operating voltages up to 60 V DC and currents up to 1 A per path, ensuring reliable data transmission.
- 5Meets UL AWM style 2464/1061 and IEC 60332-1-2 flame resistance standards, ensuring compliance in various industrial settings.
Technical Specifications
Detailed engineering parameters based on manufacturer documentation
Parameter | Value | Parameter | Value |
---|---|---|---|
Product type | System cable | Degree of protection | IP00 |
Degree of protection (Installation location) | ≥ IP54 (Installation location) | Ambient temperature (operation) | -40 °C ... 70 °C (fixed installation)
-10 °C ... 70 °C (flexible installation) |
Ambient temperature (storage/transport) | -40 °C ... 80 °C | Altitude | ≤ 2000 m |
Operating voltage (AC) | ≤ 30 V AC | Operating voltage (DC) | ≤ 60 V DC |
Nominal operating mode | 100% operating factor | Current (Per path, 50°C) | ≤ 1 A (Uncoiled, see derating) |
Current (Per path, 70°C) | ≤ 0.6 A (Uncoiled, see derating) | Cable length | 15 m |
UL AWM Style | 2464/1061 | Number of positions | 40 |
Shielded | yes | Cable type | 40X0.14 [PVC] |
Conductor type | Assembled shielded round cable | Conductor structure signal line | 7x 0.16 mm |
AWG signal line | 26 | Conductor cross section | 40x 0.14 mm² |
Wire diameter incl. insulation | 1 mm ±0.03 mm | External cable diameter | 9.80 mm ±0.3 mm |
Outer sheath, material | Semi-rigid PVC | External sheath, color | gray |
Conductor material | Tin-plated Cu litz wires | Cable resistance | ≤ 145 Ω/km (at 20 °C) |
Insulation resistance | ≥ 20 MΩ*km (20 °C) | Smallest bending radius, fixed installation | 101 mm |
Smallest bending radius, movable installation | 182 mm | Dynamic load capacity (bending) | Max. bending cycles: 5000 (at a radius of ≥ 18x outside diameter) |
Halogen-free | no | Flame resistance | IEC 60332-1-2 (raw cable)
VDE 0842, Part 332-1-2 (raw cable)
IEC 60332-3-22 (raw cable)
UL VW-1
CSA FT-1 |
Resistance to oil | can withstand occasional splashes (raw cable) | Cable type | Cable for one module |
Connection in acc. with standard | IEC 60603-13 (in compliance) | Connection method | IDC/FLK socket strip |
Number of connections | 1 | Number of positions | 24 |
Insertion/withdrawal cycles | > 50 | Pitch | 2.54 mm |
Connection in acc. with standard | IEC 60603-13 (in compliance) | Connection method | IDC/FLK socket strip |
Number of connections | 1 | Number of positions | 24 |
Note | The braided shield is routed to a separate cable end.
The separate cable end is approximately 0.5 m long (H05V-K 1 mm², black) | Insertion/withdrawal cycles | > 50 |
Pitch | 2.54 mm | Notes on operation | For proper use, the specifications of the installation directive (see Downloads) must be observed. For applications or use with third-party products, the specifications, and the safety and warning instructions of the respective third-party manufacturer must also be met. |
Specifications may be subject to change without notice