Product Model
FLK 24/EZ-DR/4000/KONFEK/S

Selling Points
- 1Ensures reliable signal transmission with a braided shield.
- 2Ideal for extended connections in industrial settings.
- 3Supports multiple connections with ease.
- 4Operates between -10°C to 70°C for flexible installations.
- 5Meets special requirements in process technology and engineering.
Technical Specifications
Detailed engineering parameters based on manufacturer documentation
Parameter | Value | Parameter | Value |
---|---|---|---|
Product type | System cable | Insulation | Functional insulation |
Overvoltage category | II | Pollution degree | 2 |
Degree of protection | IP00 | Degree of protection (Installation location) | ≥ IP54 (Installation location) |
Ambient temperature (operation) | -40 °C ... 70 °C (fixed installation)
-10 °C ... 70 °C (flexible installation) | Ambient temperature (storage/transport) | -40 °C ... 80 °C |
Altitude | ≤ 2000 m | Max. permissible operating voltage | 25 V AC
60 V DC |
Nominal operating mode | 100% operating factor | Max. current carrying capacity per path | 1 A |
Rated insulation voltage | 63 V | Rated surge voltage | 0.6 kV (1.2/50 μs) |
Cable length | 40 m | UL AWM Style | 2464/1061 |
Number of positions | 40 | Shielded | yes |
Cable type | 40X0.14 [PVC] | Conductor type | Assembled shielded round cable |
Conductor structure signal line | 7x 0.16 mm | AWG signal line | 26 |
Conductor cross section | 40x 0.14 mm² | Wire diameter incl. insulation | 1 mm ±0.03 mm |
External cable diameter | 9.80 mm ±0.3 mm | Outer sheath, material | Semi-rigid PVC |
External sheath, color | gray | Conductor material | Tin-plated Cu litz wires |
Cable resistance | ≤ 145 Ω/km (at 20 °C) | Insulation resistance | ≥ 20 MΩ*km (20 °C) |
Smallest bending radius, fixed installation | 101 mm | Smallest bending radius, movable installation | 182 mm |
Dynamic load capacity (bending) | Max. bending cycles: 5000 (at a radius of ≥ 18x outside diameter) | Halogen-free | no |
Flame resistance | IEC 60332-1-2 (raw cable)
VDE 0842, Part 332-1-2 (raw cable)
IEC 60332-3-22 (raw cable)
UL VW-1
CSA FT-1 | Resistance to oil | can withstand occasional splashes (raw cable) |
Cable type | Cable for one module | Connection in acc. with standard | IEC 60603-13 |
Connection method | IDC/FLK socket strip | Number of connections | 1 |
Number of positions | 24 | Note | The braided shield is routed to a separate cable end.
The separate cable end is approximately 0.5 m long (H05V-K 1 mm², black) |
Insertion/withdrawal cycles | > 50 | Pitch | 2.54 mm |
Connection in acc. with standard | IEC 60603-13 | Connection method | IDC/FLK socket strip |
Number of connections | 1 | Number of positions | 24 |
Insertion/withdrawal cycles | > 50 | Pitch | 2.54 mm |
Standards/regulations | DIN EN 50178 | Notes on operation | For proper use, the specifications of the installation directive (see Downloads) must be observed. For applications or use with third-party products, the specifications, and the safety and warning instructions of the respective third-party manufacturer must also be met. |
Specifications may be subject to change without notice