Product Model

FLK 40/4X14/EZ-DR/ 200/IB32

In Stock
Last updated: 2025/4/23
Phoenix Contact FLK 40/4X14/EZ-DR/ 200/IB32

Selling Points

  • 1Compatible with Allen-Bradley SLC 500 controllers.
  • 2100% operating factor for reliable performance.
  • 3IP54 protection for harsh environments.
  • 4Round cable set with 10x 0.14 mm² conductors.
  • 52-meter length with IDC/FLK socket strips (40-position and 4x 14-position).
Product Details
FLK 40/4X14/EZ-DR/ 200/IB32
Phoenix Contact

Technical Specifications

Detailed engineering parameters based on manufacturer documentation

ParameterValueParameterValue
Product type
System cable
Degree of protection
IP00
Degree of protection (Installation location)
≥ IP54 (Installation location)
Ambient temperature (operation)
-40 °C ... 70 °C (fixed installation) -10 °C ... 70 °C (flexible installation)
Ambient temperature (storage/transport)
-40 °C ... 80 °C
Altitude
≤ 2000 m
Operating voltage (AC)
≤ 30 V AC
Operating voltage (DC)
≤ 60 V DC
Nominal operating mode
100% operating factor
Current (Per path, 50°C)
≤ 1 A (Uncoiled, see derating)
Current (Per path, 70°C)
≤ 0.6 A (Uncoiled, see derating)
Suitable I/O card
1746 IB 32 1746 IV 32
Cable length
2 m
UL AWM Style
2464/1061
Number of positions
10
Shielded
no
Cable type
10X0.14 [PVC]
Conductor type
Round cable set
Conductor structure signal line
7x 0.16 mm
AWG signal line
26
Conductor cross section
10x 0.14 mm²
Wire diameter incl. insulation
1 mm ±0.03 mm
External cable diameter
6.10 mm ±0.4 mm
Outer sheath, material
Semi-rigid PVC
External sheath, color
gray
Conductor material
Tin-plated Cu litz wires
Cable resistance
≤ 145 Ω/km (20 °C)
Insulation resistance
≥ 20 MΩ*km (20 °C)
Smallest bending radius, fixed installation
52 mm
Smallest bending radius, movable installation
98 mm
Dynamic load capacity (bending)
Max. bending cycles: 5000
Halogen-free
no
Flame resistance
IEC 60332-1-2 (raw cable) VDE 0842, Part 332-1-2 (raw cable) IEC 60332-3-22 (raw cable) UL VW-1 CSA FT-1
Resistance to oil
can withstand occasional splashes (raw cable)
Cable type
Splitting cable for four modules
black
IDC/FLK40 (5) = IDC/FLK14-1 (1)
brown
IDC/FLK40 (7) = IDC/FLK14-1 (2)
red
IDC/FLK40 (9) = IDC/FLK14-1 (3)
orange
IDC/FLK40 (11) = IDC/FLK14-1 (4)
yellow
IDC/FLK40 (13) = IDC/FLK14-1 (5)
green
IDC/FLK40 (15) = IDC/FLK14-1 (6)
blue
IDC/FLK40 (17) = IDC/FLK14-1 (7)
violet
IDC/FLK40 (19) = IDC/FLK14-1 (8)
gray
IDC/FLK40 (1) = IDC/FLK14-1 (10)
white
IDC/FLK40 (3) = IDC/FLK14-1 (12)
black
IDC/FLK40 (21) = IDC/FLK14-2 (1)
brown
IDC/FLK40 (23) = IDC/FLK14-2 (2)
red
IDC/FLK40 (25) = IDC/FLK14-2 (3)
orange
IDC/FLK40 (27) = IDC/FLK14-2 (4)
yellow
IDC/FLK40 (29) = IDC/FLK14-2 (5)
green
IDC/FLK40 (31) = IDC/FLK14-2 (6)
blue
IDC/FLK40 (33) = IDC/FLK14-2 (7)
violet
IDC/FLK40 (35) = IDC/FLK14-2 (8)
gray
IDC/FLK40 (37) = IDC/FLK14-2 (10)
white
IDC/FLK40 (39) = IDC/FLK14-2 (12)
black
IDC/FLK40 (6) = IDC/FLK14-3 (1)
brown
IDC/FLK40 (8) = IDC/FLK14-3 (2)
red
IDC/FLK40 (10) = IDC/FLK14-3 (3)
orange
IDC/FLK40 (12) = IDC/FLK14-3 (4)
yellow
IDC/FLK40 (14) = IDC/FLK14-3 (5)
green
IDC/FLK40 (16) = IDC/FLK14-3 (6)
blue
IDC/FLK40 (18) = IDC/FLK14-3 (7)
violet
IDC/FLK40 (20) = IDC/FLK14-3 (8)
gray
IDC/FLK40 (2) = IDC/FLK14-3 (10)
white
IDC/FLK40 (4) = IDC/FLK14-3 (12)
black
IDC/FLK40 (22) = IDC/FLK14-4 (1)
brown
IDC/FLK40 (24) = IDC/FLK14-4 (2)
red
IDC/FLK40 (26) = IDC/FLK14-4 (3)
orange
IDC/FLK40 (28) = IDC/FLK14-4 (4)
yellow
IDC/FLK40 (30) = IDC/FLK14-4 (5)
green
IDC/FLK40 (32) = IDC/FLK14-4 (6)
blue
IDC/FLK40 (34) = IDC/FLK14-4 (7)
violet
IDC/FLK40 (36) = IDC/FLK14-4 (8)
gray
IDC/FLK40 (38) = IDC/FLK14-4 (10)
white
IDC/FLK40 (40) = IDC/FLK14-4 (12)
Connection in acc. with standard
IEC 60603-13 (in compliance)
Connection method
IDC/FLK socket strip
Number of connections
1
Number of positions
40
Insertion/withdrawal cycles
> 50
Pitch
2.54 mm
Connection in acc. with standard
IEC 60603-13 (in compliance)
Connection method
IDC/FLK socket strip
Number of connections
4
Number of positions
14
Insertion/withdrawal cycles
> 50
Pitch
2.54 mm
Notes on operation
For proper use, the specifications of the installation directive (see Downloads) must be observed. For applications or use with third-party products, the specifications, and the safety and warning instructions of the respective third-party manufacturer must also be met.

Specifications may be subject to change without notice