Product Model

FLK 40-PA/EZ-DR/HF/KS/ 700/YUC

In Stock
Last updated: 2025/4/17
Phoenix Contact FLK 40-PA/EZ-DR/HF/KS/ 700/YUC

Selling Points

  • 1High-quality materials: Made with Cu tin-plated single wires for durability and reliability.
  • 2Halogen-free cable: Ensures safety in various industrial applications.
  • 350-pos. socket strip: Provides versatile connection options for Yokogawa systems.
  • 4Compact design: Suitable for fixed installations with a smallest bending radius of 102 mm.
  • 5Compliant with UL standards: Meets structural data requirements according to UL style 2464/1061.
Product Details
FLK 40-PA/EZ-DR/HF/KS/ 700/YUC
Phoenix Contact

Technical Specifications

Detailed engineering parameters based on manufacturer documentation

ParameterValueParameterValue
Product type
Front adapter
Article revision
05
Operating voltage (DC)
≤ 30 V DC
Nominal operating mode
100% operating factor
Current (Per path)
≤ 500 mA (uncoiled)
Suitable I/O card
AAI543 AAI141 AAI143 AAI835 AAI841 AAI135 AAR181 AAT141 AAV141 AAV142 AAB841 AAV542
Suitable I/O card
NFAI543 NFAI141 NFAI143 NFAI835 NFAI841 NFAI135 NFAV141 NFAV142 NFAB841 NFAV542
Suitable I/O card
SAI143 SAV144 SAI533
Connection in acc. with standard
IEC 60603-13 (in compliance)
Connection method
Yokogawa, I/O cards compatible
Number of connections
1
Number of positions
40
Tightening torque
0.5 Nm (Screw connection)
Insertion/withdrawal cycles
> 50
Pitch
2.54 mm
Connection in acc. with standard
IEC 60603-13 (in compliance)
Connection method
Yokogawa, KS compatible
Number of connections
1
Number of positions
40
Tightening torque
0.5 Nm (Screw connection)
Insertion/withdrawal cycles
> 50
Pitch
2.54 mm
Length
7 m
Number of positions
40
Shielded
yes
Conductor type
Assembled, shielded, halogen-free round cable
Conductor structure signal line
7x 0.16 mm
AWG signal line
26
Conductor cross section
40x 0.14 mm²
Wire diameter incl. insulation
1 mm ±0.03 mm
External cable diameter
9.80 mm ±0.4 mm
Outer sheath, material
Halogen-free sheath
External sheath, color
gray
Conductor material
Tin-plated Cu litz wires
Cable resistance
≤ 145 Ω/km
Insulation resistance
≥ 20 MΩ*km
Smallest bending radius, fixed installation
102 mm
Smallest bending radius, movable installation
184 mm
Dynamic load capacity (bending)
Max. bending cycles: 5000
Halogen-free
yes
Flame resistance
IEC 60332-1-2 (raw cable) VDE 0842, Part 332-1-2 (raw cable) IEC 60332-3-22 (raw cable)
Resistance to oil
can withstand occasional splashes (raw cable)
Degree of protection
IP20
Degree of protection (Installation location)
≥ IP54 (Installation location)
Ambient temperature (operation)
-40 °C ... 70 °C (fixed installation) -10 °C ... 70 °C (flexible installation)
Ambient temperature (storage/transport)
-40 °C ... 80 °C
Altitude
≤ 2000 m
Certificate
UKCA-compliant
Mounting position
any
Notes on operation
For proper use, the specifications of the installation directive (see Downloads) must be observed. For applications or use with third-party products, the specifications, and the safety and warning instructions of the respective third-party manufacturer must also be met.