Product Model

FLK 50-PA/EZ-DR/KS/2500/YOC

In Stock
Last updated: 2025/4/21
Phoenix Contact FLK 50-PA/EZ-DR/KS/2500/YOC

Selling Points

  • 1High-quality front adapter for Yokogawa ProSafe controllers.
  • 250-position socket strip injection-molded on both sides.
  • 310m shielded cable with 50X0.14 PVC, UL AWM style 2464/1061.
  • 40.5Nm tightening torque ensures secure connections.
  • 5Compatible with Yokogawa ProSafe-RS and SDV531 I/O cards.
Product Details
FLK 50-PA/EZ-DR/KS/2500/YOC
Phoenix Contact

Technical Specifications

Detailed engineering parameters based on manufacturer documentation

ParameterValueParameterValue
Product type
Front adapter
Article revision
10
Operating voltage (DC)
≤ 30 V DC
Nominal operating mode
100% operating factor
Current (Per path)
≤ 500 mA (uncoiled)
Suitable I/O card
SDV531 SDV531L
Connection in acc. with standard
IEC 60603-13 (in compliance)
Connection method
Yokogawa, I/O cards compatible
Number of connections
1
Number of positions
50
Tightening torque
0.5 Nm (Screw connection)
Insertion/withdrawal cycles
> 50
Pitch
2.54 mm
Connection in acc. with standard
IEC 60603-13 (in compliance)
Connection method
Yokogawa, KS compatible
Number of connections
1
Number of positions
50
Tightening torque
0.5 Nm (Screw connection)
Insertion/withdrawal cycles
> 50
Pitch
2.54 mm
Length
25 m
UL AWM Style
2464/1061
Number of positions
50
Shielded
yes
Cable type
50X0.14 [PVC]
Conductor type
Assembled shielded round cable
Conductor structure signal line
7x 0.16 mm
AWG signal line
26
Conductor cross section
50x 0.14 mm²
Wire diameter incl. insulation
1 mm ±0.03 mm
External cable diameter
11.00 mm ±0.3 mm
Outer sheath, material
Semi-rigid PVC
External sheath, color
gray
Conductor material
Tin-plated Cu litz wires
Cable resistance
≤ 145 Ω/km (at 20 °C)
Insulation resistance
≥ 20 MΩ*km (20 °C)
Smallest bending radius, fixed installation
114 mm
Smallest bending radius, movable installation
205 mm
Dynamic load capacity (bending)
Max. bending cycles: 5000 (at a radius of ≥ 18x outside diameter)
Halogen-free
no
Flame resistance
IEC 60332-1-2 (raw cable) VDE 0842, Part 332-1-2 (raw cable) IEC 60332-3-22 (raw cable) UL VW-1 CSA FT-1
Resistance to oil
can withstand occasional splashes (raw cable)
Degree of protection
IP20
Degree of protection (Installation location)
≥ IP54 (Installation location)
Ambient temperature (operation)
-40 °C ... 70 °C (fixed installation) -10 °C ... 70 °C (flexible installation)
Ambient temperature (storage/transport)
-40 °C ... 80 °C
Altitude
≤ 2000 m
Certificate
UKCA-compliant
Mounting position
any
Notes on operation
For proper use, the specifications of the installation directive (see Downloads) must be observed. For applications or use with third-party products, the specifications, and the safety and warning instructions of the respective third-party manufacturer must also be met.

Specifications may be subject to change without notice