Product Model
FLKM 14-PA-MELSEC A1S/A

Selling Points
- 1Connects 2 x 8 channels to Mitsubishi Electric MELSEC A1S X80 and X80-1.
- 2Functional insulation with overvoltage category II and pollution degree 2.
- 3Operating voltage up to 30 V DC, current per path ≤ 1 A, and rated insulation voltage of 50 V.
- 4Can be mounted in any position, ensuring adaptability in various industrial settings.
- 5Meets IEC 60664 and DIN EN 50178 standards for safety and reliability.
Technical Specifications
Detailed engineering parameters based on manufacturer documentation
Parameter | Value | Parameter | Value |
---|---|---|---|
Product type | Front adapter | Overvoltage category | II |
Pollution degree | 2 | Max. permissible current | 1 A (per path) |
Connection method | IDC/FLK pin strip | Number of connections | 2 |
Number of positions | 14 | Pitch | 2.54 mm |
Mounting position | any | Notes on operation | For proper use, the specifications of the installation directive (see Downloads) must be observed. For applications or use with third-party products, the specifications, and the safety and warning instructions of the respective third-party manufacturer must also be met. |
Specifications may be subject to change without notice