Product Model

FLKM 40/ZFKDS

In Stock
Last updated: 2025/4/23
Phoenix Contact FLKM 40/ZFKDS

Selling Points

  • 1Standard 1:1 FLK Module: The FLKM 40/ZFKDS is a standard 1:1 FLK module designed for reliable connectivity.
  • 2Spring-Cage Connection: Equipped with a spring-cage connection for secure and efficient signal transfer.
  • 3Functional Insulation: Offers functional insulation for enhanced electrical safety and performance.
  • 4Allen-Bradley SLC 500 Support: Compatible with Allen-Bradley SLC 500 controllers, ensuring seamless integration in industrial settings.
  • 5Durable Design: Built to withstand harsh industrial environments with an operating temperature range of -20°C to 50°C.
Product Details
FLKM 40/ZFKDS
Phoenix Contact

Technical Specifications

Detailed engineering parameters based on manufacturer documentation

ParameterValueParameterValue
Product type
Interface module
Product family
VARIOFACE
Number of positions
40
No. of channels
2 4 6 8 16 32
Article revision
06
Insulation
Functional insulation
Overvoltage category
II
Pollution degree
2
Operating voltage (AC)
≤ 30 V AC
Operating voltage (DC)
≤ 60 V DC
Current (per branch)
≤ 1 A
Rated insulation voltage
63 V
Rated surge voltage
0.6 kV (1.2/50 μs)
Suitable I/O card
1746 OB 32 1746 OV 32 1746 IB 32 1746 IV 32
Connection in acc. with standard
IEC 60603-13
Connection method
IDC/FLK pin strip
Number of connections
1
Number of positions
40
Insertion/withdrawal cycles
> 50
Pitch
2.54 mm
Connection method
Spring-cage connection
Stripping length
7 mm
Number of positions
40
Conductor cross section rigid
0.2 mm² ... 4 mm²
Conductor cross section flexible
0.2 mm² ... 2.5 mm² 0.25 mm² ... 2.5 mm² (Ferrule without plastic sleeve) 0.25 mm² ... 1.5 mm² (Ferrule with plastic sleeve)
Conductor cross section AWG
24 ... 12
Pitch
5.08 mm
Status display present
No
Width
112.5 mm
Height
77 mm
Depth
52.34 mm
Color
green (RAL 6021)
Degree of protection (Module)
IP00
Degree of protection (Installation location)
≥ IP54
Ambient temperature (operation)
-20 °C ... 50 °C
Ambient temperature (storage/transport)
-20 °C ... 70 °C
Altitude
≤ 2000 m
Standards/regulations
EN IEC 60664-1
Mounting type
DIN rail mounting
Mounting position
any
Notes on operation
For proper use, the specifications of the installation directive (see Downloads) must be observed. For applications or use with third-party products, the specifications, and the safety and warning instructions of the respective third-party manufacturer must also be met.

Specifications may be subject to change without notice