Product Model

FLKM-D37 SUB/B/ZFKDS

In Stock
Last updated: 2025/4/18
Phoenix Contact FLKM-D37 SUB/B/ZFKDS

Selling Points

  • 1High-Quality Connectivity: Reliable 37-position D-SUB socket strip for secure data transmission.
  • 2Spring-Cage Connection: Easy and secure connection technology according to IEC 60807-2.
  • 3Wide Operating Range: Operates within -20 °C to 50 °C ambient temperature range.
  • 4Compliant with Standards: Meets IEC 60664, DIN EN 50178, and other industry standards for safety and reliability.
  • 5Versatile Mounting Options: Can be mounted in any position, including DIN rail mounting for flexibility in installation.
Product Details
FLKM-D37 SUB/B/ZFKDS
Phoenix Contact

Technical Specifications

Detailed engineering parameters based on manufacturer documentation

ParameterValueParameterValue
Product type
Interface module
Number of positions
37
Article revision
07
Insulation
Functional insulation
Overvoltage category
II
Pollution degree
2
Operating voltage (AC)
≤ 30 V AC
Operating voltage (DC)
≤ 60 V DC
Current (per branch)
≤ 2.5 A
Current (Total current)
≤ 81.4 A
Rated insulation voltage
125 V
Rated surge voltage
1.2 kV (1.2/50 μs)
Connection in acc. with standard
IEC 60807-2
Connection method
D-SUB socket strip
Screw thread
UNC 4-40
Number of connections
1
Number of positions
37
Insertion/withdrawal cycles
> 500
Pitch
2.77 mm
Connection method
Spring-cage connection
Stripping length
7 mm
Number of positions
38
Conductor cross section rigid
0.2 mm² ... 4 mm²
Conductor cross section flexible
0.2 mm² ... 2.5 mm² 0.25 mm² ... 2.5 mm² (Ferrule without plastic sleeve) 0.25 mm² ... 1.5 mm² (Ferrule with plastic sleeve)
Conductor cross section AWG
24 ... 12
Pitch
5.08 mm
Status display
no
Status display present
No
Width
101.25 mm
Height
77 mm
Depth
51.27 mm
Color
green (RAL 6021)
Housing insulation material
PVC
Degree of protection (Module)
IP20
Degree of protection (Installation location)
≥ IP54
Ambient temperature (operation)
-20 °C ... 50 °C
Ambient temperature (storage/transport)
-20 °C ... 70 °C
Altitude
≤ 2000 m
Certificate
UKCA-compliant
Standards/regulations
EN IEC 60664-1
Mounting type
DIN rail mounting
Mounting position
any
Notes on operation
For proper use, the specifications of the installation directive (see Downloads) must be observed. For applications or use with third-party products, the specifications, and the safety and warning instructions of the respective third-party manufacturer must also be met.

Specifications may be subject to change without notice