Product Model
FL MEM PLUG

Selling Points
- 1Easily change and set up device settings with our FL MEM PLUG/MRM.
- 2The MRM license is stored within the Media Redundancy protocol (MRP) for enhanced reliability.
- 3Free next-working-day delivery for orders placed before 3:30 PM in Turkey.
- 4Available in various regions with extended lead times for global stock.
- 5Products are under manufacturer warranty unless specified otherwise, ensuring quality and reliability.
Technical Specifications
Detailed engineering parameters based on manufacturer documentation
Parameter | Value | Parameter | Value |
---|---|---|---|
Note on application | Only for industrial use | Product type | Storage medium |
Type | fine granularity | Memory type | FLASH-EPROM 64 kByte |
Basic functions | Configuration memory (plug-in) | Maximum power dissipation for nominal condition | max. 0.02 W |
Power supply connection | from FL SWITCH MCS/SMCS | Width | 16 mm |
Height | 49 mm | Color | green |
Degree of protection | IP20 | Ambient temperature (operation) | 0 °C ... 55 °C (non-condensing) |
Ambient temperature (storage/transport) | -20 °C ... 70 °C | Permissible humidity (operation) | 10 % ... 95 % (non-condensing) |
Permissible humidity (storage/transport) | 10 % ... 95 % (non-condensing) | Electromagnetic compatibility | Conformance with EMC Directive 2004/108/EC |
Conformance with EMC directives | IEC 61000-6-2 IEC 61000-4-2 (ESD) Criterion B
IEC 61000-4-3 (immunity to radiated interference) Criterion A
IEC 61000-4-4 (burst) Criterion A
IEC 61000-4-5 (surge) Criterion A
IEC 61000-4-6 (immunity to conducted interference) Criterion A
IEC 61000-4-8 (immunity to magnetic fields) Criterion A
EN 55022 (emitted interference) Criterion A | Noise immunity | EN 61000-6-2:2005 |
Noise emission | EN 61000-6-3/-4 | Mounting type | In the host system |
Specifications may be subject to change without notice