Product Model

FL MGUARD DELTA TX/TX

In Stock
Last updated: 2025/4/21
Phoenix Contact FL MGUARD DELTA TX/TX

Selling Points

  • 1Advanced intelligent firewall with stateful inspection for maximum security.
  • 2Supports up to 10 VPN tunnels (up to 250 with additional license).
  • 3Includes CIFS Integrity Monitoring for data protection.
  • 4Metal housing for durability and robust design.
  • 5Web-based management and SNMP support for easy configuration.
Product Details
FL MGUARD DELTA TX/TX
Phoenix Contact

Technical Specifications

Detailed engineering parameters based on manufacturer documentation

ParameterValueParameterValue
Width
130 mm
Height
50 mm
Depth
114 mm
Color
silver
Housing material
Metal
Connection method
RJ45
Transmission speed
10/100 Mbps
Transmission physics
Ethernet in RJ45 twisted pair
Transmission length
100 m (per segment)
Signal LEDs
Supply voltage, data transmission, error, link, activity
No. of channels
2 (RJ45)
Basic functions
Router with intelligent firewall (VPN, 10 tunnels as an option, up to 250 possible with additional license), CIFS Integrity Monitoring (as an option), metal housing, slot for SD memory card, extended temperature range, high-performance firewall/VPN (as an option): up to 99 Mbps / 35 Mbps (as an option)
Supported browsers
HTTPS support required
Product type
Security routers without DIN rail mounting
Protection class
III (IEC 61140, EN 61140, VDE 0140-1)
Local diagnostics
Green LED One LED per port Link active Green LED
Maximum power dissipation for nominal condition
2.99 W
Supply voltage (AC)
230 V AC
Supply voltage range
90 V AC ... 264 V AC ((50/60 Hz))
Max. current consumption
40 mA
Typical current consumption
13 mA
Connection method
RJ45, shielded
Degree of protection
IP20
Ambient temperature (operation)
5 °C ... 40 °C
Ambient temperature (storage/transport)
-20 °C ... 70 °C
Permissible humidity (operation)
5 % ... 95 % (non-condensing)
Electromagnetic compatibility
Conformance with EMC Directive 2014/30/EU
Noise immunity
EN 61000-6-2:2005
Noise emission
EN 55022 / Class B
Status display
LEDs:P1, P2, Fault, State, Error, LAN, WAN

Specifications may be subject to change without notice