Product Model
FL MGUARD GT/GT

Selling Points
- 1Intelligent stateful inspection firewall for maximum security.
- 2Gigabit connectivity with SFP slots for high-speed data transfer.
- 3Secure remote services via IPsec standard VPN.
- 4Replaceable configuration memory for easy updates.
- 5Comprehensive connection options including Ethernet and fiber optic interfaces.
Technical Specifications
Detailed engineering parameters based on manufacturer documentation
Parameter | Value | Parameter | Value |
---|---|---|---|
Width | 128 mm | Height | 110 mm |
Depth | 69 mm | Note on application | Only for industrial use |
Color | gray aluminum | Housing material | Metal |
Connection method | SFP/RJ45 | Note on the connection method | Either SFP port or RJ45 port active |
Transmission speed | 10/100/1000 Mbps (SFP module: 100/1000 Mbps) | Transmission physics | Copper or SFP module |
Transmission length | 100 m (per segment) | Signal LEDs | Supply voltage, data transmission, error, link, activity |
No. of channels | 2 (Combo ports) | Connection method | RS-232-C, 6-pos. MINI-DIN socket (PS/2) |
Connection method | SFP | Transmission speed | 1000 Mbps (full duplex) |
Transmission physics | Depending on the SFP module | Transmission length | up to 80 km (Depending on the fiber/SFP module used) |
Basic functions | Router with intelligent firewall and Gigabit connectivity | Supported browsers | HTTPS support required |
Product type | Security router for the DIN rail | Type | Stand-Alone |
Article revision | 09 | Protection class | III (IEC 61140, EN 61140, VDE 0140-1) |
Number of VPN tunnels | 0 (up to 250 tunnels with additional license as an option) | Data integrity | MD5, SHA-1, SHA 256, SHA-512 |
Dynamic Host Configuration Protocol (DHCP) support | Server or Relay Agent | Filtering | MAC and IP addresses, ports, protocols |
Firewall data throughput | max. 417 Mbps (Router mode, default firewall rules, bidirectional throughput)
max. 174 Mbps (Stealth mode, default firewall rules, bidirectional throughput) | Firewall rules | Configurable stateful inspection firewall |
Basic functions | Router with intelligent firewall and Gigabit connectivity | Link Layer Discovery Protocol (LLDP) | As per protocol 802.2 |
Network Time Protocol (NTP) client | Client | Remote Syslog Logging | on externals server |
Routing | Standard routing, NAT, 1:1-NAT, port forwarding | Protection against | IP spoofing, DoS and Syn Flood Protection |
Encryption methods | DES, 3DES, AES-128, -192, -256 | Virtual private network (VPN) throughput | max. 106 Mbps (Router mode, VPN bidirectional throughput) |
Power consumption | 6.5 W | Maximum power dissipation for nominal condition | typ. 6.48 W |
Test section | 500 V DC 1 min | Supply voltage (DC) | 24 V DC (redundant) |
Supply voltage range | 18 V DC ... 32 V DC | Power supply connection | Via COMBICON, max. conductor cross section 2.5 mm² |
Residual ripple | 3.6 V | Max. current consumption | 270 mA |
Typical current consumption | 270 mA (at U | Signal contact control voltage | 24 V DC (typical) |
Signal contact control current | 270 mA (typical) | Degree of protection | IP20 |
Ambient temperature (operation) | -20 °C ... 60 °C | Ambient temperature (storage/transport) | -40 °C ... 85 °C |
Permissible humidity (operation) | 5 % ... 95 % (non-condensing) | Permissible humidity (storage/transport) | 5 % ... 95 % (non-condensing) |
Shock | DIN EN 60068-2-27 | Vibration (operation) | in accordance with IEC 60068-2-6: 5g, 10 Hz ... 150 Hz |
Air pressure (operation) | 86 hPa ... 108 kPa (1500 m above sea level) | Air pressure (storage/transport) | 66 hPa ... 108 kPa (3500 m above sea level) |
Free from substances that could impair the application of coating | In acc. with VW specification | Mounting type | DIN rail mounting |
Electromagnetic compatibility | Conformance with EMC Directive 2014/30/EU | Conformance with EMC directives | IEC 61000-6-2 IEC 61000-4-2 (ESD) 6 kV contact discharge, 8 kV air discharge
IEC 61000-6-2 IEC 61000-4-3 (immunity to radiated interference) 10 V/m (80 MHz ... 2000 MHz)
IEC 61000-6-2 IEC 61000-4-4 (burst) 2 kV power line, 1kV data line
IEC 61000-6-2 IEC 61000-4-5 (surge) power line: 2 kV (line/earth), 1 kV (line/line), 1 kV data line
IEC 61000-6-2 IEC 61000-4-6 (immunity to conducted interference) 3 V (10 kHz ... 150 kHz), 10 V (150 kHz ... 80 MHz) |
Noise immunity | EN 61000-6-2:2005 | Noise emission | EN 61000-6-4 |
Status display | LEDs: LNK, Mode, Inf, ACT, SPD, FD, US1, US2, Fail, and 7-segment display |
Specifications may be subject to change without notice