Product Model
FLM TEMP 4 RTD M12

Selling Points
- 1Flexible power supply concept for reliable operation.
- 2SPEEDCON fast locking system for secure connections.
- 3Diagnostic and status indicators for real-time monitoring.
- 4Short-circuit and overload protection for safety.
- 5Consistent connection via M12 connectors for easy integration.
Technical Specifications
Detailed engineering parameters based on manufacturer documentation
Parameter | Value | Parameter | Value |
---|---|---|---|
Width | 70 mm | Height | 178 mm |
Depth | 50 mm | Drill hole spacing | 168 mm |
Note on application | Only for industrial use | Color | anthracite |
Connection method | M12 connector, B-coded | Transmission speed | 500 kbps / 2 Mbps |
Transmission physics | Copper | ID code (dec.) | 223 |
ID code (hex) | DF | Length code (hex) | 05 |
Length code (dec) | 05 | Process data channel | 80 bit |
Input address area | 10 Byte | Output address area | 10 Byte |
Register length | 96 bit | Required parameter data | 17 Byte |
Required configuration data | 5 Byte | Number of inputs | max. 4 (for resistance temperature detectors) |
Connection method | M12 connector | Connection technology | 2-, 3-, 4-conductor (shielded) |
Number of inputs | max. 4 (for resistance temperature detectors) | Connection method | M12 connector |
Connection technology | 2-, 3-, 4-conductor (shielded) | Sensor types (RTD) that can be used | Pt, Ni, KTY sensors, linear resistors |
Input filter time | 4.1 ms (default setting or 0.6 ms; adjustable for each channel) | Process data update | Dependent on the connection method |
Product type | I/O component | Type | modular |
Voltage supply U | 24 V DC | Power supply at U | max. 4 A |
Current consumption from U | max. 100 mA (At 2 Mbaud)
typ. 70 mA | Voltage supply U | 24 V DC |
Power supply at U | max. 4 A | Current consumption from U | typ. 5 mA (plus power supply for sensors)
max. 400 mA |
Supply voltage | 24 V DC | Supply voltage range | 18 V DC ... 30 V DC (including ripple) |
Connection method | M12 connector | Ambient temperature (operation) | -25 °C ... 60 °C |
Degree of protection | IP65/IP67 | Air pressure (operation) | 80 kPa ... 106 kPa (up to 2000 m above sea level) |
Air pressure (storage/transport) | 70 kPa ... 106 kPa (up to 3000 m above sea level) | Ambient temperature (storage/transport) | -25 °C ... 85 °C |
Permissible humidity (storage/transport) | 95 % | Protection class | III (IEC 61140, EN 61140, VDE 0140-1) |
Mounting type | Wall mounting |
Specifications may be subject to change without notice