Phoenix Contact FL NAT 2304-2GC-2SFP

Selling Points

  • 1High-Speed Connectivity: Supports 10/100/1000 Mbps on RJ45 ports and 100/1000 Mbps on SFP ports.
  • 2Flexible Port Options: Includes 4 RJ45 ports, 2 SFP ports, and 2 combo ports for versatile connectivity.
  • 3Advanced Networking Features: Compliant with IEEE 802.3, supports RSTP, MRP, and LACP for robust network management.
  • 4Industrial-Grade Reliability: Designed for extended temperature range (-40°C to 70°C) and high humidity environments.
  • 5Secure and Manageable: Offers port security, MAC-based authentication, and web-based management via HTTP/HTTPS.
Product Details
FL NAT 2304-2GC-2SFP
Phoenix Contact

Technical Specifications

Detailed engineering parameters based on manufacturer documentation

ParameterValueParameterValue
Width
45 mm
Height
130 mm
Depth
115 mm
General
Support by phone or on-site (fee is charged)
Note on application
Only for industrial use
Housing material
Polycarbonate fiber reinforced
Mounting type
DIN rail mounting
Connection method
RJ45
Note on the connection method
Auto negotiation and autocrossing
Transmission speed
10/100/1000 Mbps
Transmission physics
Copper
Transmission length
100 m (per segment)
Signal LEDs
Data receive, link status
No. of channels
4 (RJ45 ports)
Number of interfaces
2
Connection method
SFP
Transmission speed
100/1000 Mbps (full duplex)
Transmission physics
Depending on the SFP module
Transmission length
up to 80 km (Depending on the fiber/SFP module used)
Signal LEDs
Data receive, link status
No. of channels
2 (SFP ports)
Number of interfaces
2
Connection method
SFP/RJ45
Note on the connection method
Auto negotiation and autocrossing
Transmission speed
10/100/1000 Mbps (full duplex)
Transmission physics
Depending on the SFP module
Transmission length
up to 80 km (Depending on the fiber/SFP module used)
Signal LEDs
Data receive, link status
No. of channels
2 (Combo ports)
Output name
Alarm output
Product type
Switch
Product family
Managed NAT Switch 2000
Type
Book type
MTTF
362.94 Years (SN 29500 standard, temperature 25°C, operating cycle 21%) 158.13 Years (SN 29500 standard, temperature 40°C, operating cycle 34.25%) 19.77 Years (SN 29500 standard, temperature 70°C, operating cycle 100%)
Special properties
1:1-NAT, Virtual NAT, IP-Masquerading Development process certified in accordance with IEC 62443-4-1 Compatible with IEC 62443-4-2
Signal delay
≥ 1.9 µs (Store-and-Forward mode, 10/100/1000 Mbps, depending on the frame size)
Article revision
05
Protection class
III (VDE 0106)
Degree of pollution
2
Diagnostic functions
RMON History LLDP (Link Layer Discovery Protocol) SNMP-Traps N:1-Portmirroring ACD (Address Conflict Detection) SysLog CRC-Surveillance
Basic functions
Store-and-forward switch, complies with IEEE 802.3
Signal contact control voltage
typ. 24 V DC
NAT functions
1:1-NAT Virtual-NAT IP-Masquerading Port forwarding
PROFINET conformance class
Conformance-Class B
PROFINET device function
PROFINET device
Filter functions
Quality of Service (8 priority classes) Class of Service DiffServ/DSCP Port-Priorisierung VLAN (up to 32 VLANs) IGMP Snooping/Querier (v1/v2) Auto-Query-Port Extended Multicast Filtering
IP parameterization
DHCP client DHCP Option 82 (Relay Agent) DHCP server (pool-based, port-based) BootP DCP (Discovery and Configuration Protocol)
MAC address table
8k
Management
Web-based management (HTTP/HTTPS) Role-based user management (LDAP, RADIUS) SNMPv1/v2/v3 Command Line Interface (Telnet, SSH)
Redundancy
MRP (Media Redundancy Protocol) RSTP (Rapid Spanning Tree Protocol) FRD (Fast Ring Detection) Large Tree Support LACP (Link Aggregation Control Protocol) PROFINET S2 system redundancy
Status and diagnostic indicators
LEDs: US1, US2 (power supply), Fail (alarm contact), 2 LEDs per Ethernet port (Link/Activity and Speed)
Additional functions
Jumbo frames (max. 9,600 bytes)
Time synchronization
SNTP (Simple Network Time Protocol)
Port security
MAC-based, RADIUS (IEEE 802.1X), MAC Authentication Bypass
Basic functions
Store-and-forward switch, complies with IEEE 802.3
Current consumption
290 mA
Local diagnostics
US1/2 Supply voltage US1, US2 Green LED FAIL Div. LED red LINK Link status Green LED
Maximum power dissipation for nominal condition
9 W (At U
Test section
500 V DC 1 min
Transmission medium
Copper FO
Supply voltage (DC)
24 V DC (redundant)
Supply voltage range
12 V DC ... 57 V DC
Power supply connection
via COMBICON, max. conductor cross section 1.5 mm²
Residual ripple
3.6 V
Max. current consumption
1.5 A (U
Typical current consumption
290 mA (at U
Current consumption
290 mA
Signal contact control voltage
typ. 24 V DC
Connection method
Screw connection
Note on the connection method
Use only copper connecting cables providing the permitted temperature range (-40 °C ... 75 °C).
Conductor cross section, rigid
0.08 mm² ... 1.5 mm²
Conductor cross section, flexible
0.08 mm² ... 1.5 mm²
Conductor cross section AWG
28 ... 16
Stripping length
7 mm
Degree of protection
IP20
Ambient temperature (operation)
-40 °C ... 70 °C
Ambient temperature (storage/transport)
-40 °C ... 85 °C
Permissible humidity (operation)
10 % ... 95 % (non-condensing)
Permissible humidity (storage/transport)
10 % ... 95 % (non-condensing)
Shock (operation)
30g (EN 60068-2-27)
Vibration (operation)
in acc. with IEC 60068-2-6: 5g, 150 Hz
Air pressure (operation)
80 kPa ... 110 kPa up to 2000 m above mean sea level (Without derating)
Air pressure (storage/transport)
79 kPa ... 108 kPa up to 2000 m above mean sea level (Without derating)
Free from substances that could impair the application of coating
Yes
Identification
 II 3 G Ex ec IIC T4 Gc
Certificate
DEMKO 16 ATEX 1709X
References to standards
EN 60079-0 EN 60079-7
Identification
Ex ec IIC T4 Gc
Certificate
IECEx ULD 16.0018 X
References to standards
IEC 60079-0 IEC 60079-7
Identification
cULus
Identification
Class I, Division 2, Groups A, B, C, and D, T4 Class I, Zone 2, AEx ec IIC T4 Ex ec IIC T4 Gc X
Certificate
E366272
Note
UL 60079-0 Ed. 6 / UL 60079-7 Ed. 5, CSA 22.2 No. 60079-0 Ed. 3 / CSA C22.2 No. 60079-7 Ed. 2
Identification
2Ex e IIC T4 Gc X
Certificate
RU C-DE.HB49.B.00118/21
Identification
Install the device in a suitable, approved housing with at least IP66 protection. The housing/control cabinet must be equipped with a warning sign prohibiting opening in the potentially explosive area. The operation of devices is permitted if all optical ports are connected or sealed with the supplied filler plugs.
Identification
Ex ec IIC T4 Gc
Certificate
2022122310115629
Identification
ISA S71.04.2013 G3 Harsh Group A
Identification
 II 3 G Ex ec IIC T4 Gc
Certificate
PxCIMA22UKEX2702910X
Temperature
B
Humidity
B
Vibration
A
EMC
B
Enclosure
Required protection according to the Rules shall be provided upon installation on board
Electromagnetic compatibility
Conformance with EMC Directive 2014/30/EU
Conformance with EMC directives
EN 61000-6-2 EN 61000-4-2 (ESD) Criterion B EN 61000-6-2 EN 61000-4-3 (electromagnetic fields) Criterion A EN 61000-6-2 EN 61000-4-4 (EFT burst) Criterion A EN 61000-6-2 EN 61000-4-5 (surge) Criterion A EN 61000-6-2 EN 61000-4-6 (line noise immunity) Criterion A EN 61000-6-2 EN 61000-6-4 (interference) Class A EN 61000-6-2 EN 61000-6-4 (conducted interference) Class A
Noise immunity
EN 61000-6-2
Noise emission
EN 61000-6-4
Basic functions
Store-and-forward switch, complies with IEEE 802.3
Status display
LEDs: US1, US2 (power supply), Fail (alarm contact), 2 LEDs per Ethernet port (Link/Activity and Speed)

Specifications may be subject to change without notice