Selling Points

  • 1Supports data transmission speeds of up to 1000 Mbps.
  • 2Designed for long-haul applications with a maximum transmission length of 80 km.
  • 3Utilizes single-mode fiberglass with a wavelength of 1550 nm.
  • 4Operates in ambient temperatures from -40°C to 85°C and withstands humidity levels from 30% to 95%.
  • 5Meets WEEE/RoHS compliance and is certified by CUL and UL.
Product Details
FL SFP LH
Phoenix Contact

Technical Specifications

Detailed engineering parameters based on manufacturer documentation

ParameterValueParameterValue
Width
13.7 mm
Height
8.95 mm
Length
56.5 mm
Note on application
Only for industrial use
Housing material
Metal
Mounting type
Insert in SFP slot
Connection method
LC
Transmission speed
1 Gbps
Transmit capacity, minimum
0 dBm
Transmit capacity, maximum
5 dBm
Minimum receiver sensitivity
-24 dBm
Maximum receiver sensitivity
-3 dBm
Transmission physics
Single-mode fiberglass
Transmission length
80 km (Fiberglass 9/125)
Wavelength
1550 nm
Signal LEDs
depending on the Factoryline device
No. of channels
1 (LC single mode)
Transmit capacity, minimum
0 dBm
Transmit capacity, maximum
5 dBm
Minimum receiver sensitivity
-3 dBm
Maximum receiver sensitivity
-24 dBm
Product type
SFP module
Type
Factoryline devices with SFP slot
Format
SFP (Small Form-factor Pluggable)
Article revision
02
Status display
via a Factoryline device
Current consumption
300 mA
Maximum power dissipation for nominal condition
1 W
Transmission medium
FO
Supply voltage
3.3 V (via Factoryline switch)
Power supply connection
via SFP slot
Max. current consumption
300 mA
Current consumption
300 mA
Connection method
To insert in SFP slot
Degree of protection
IP20
Ambient temperature (operation)
-40 °C ... 85 °C (non-condensing)
Ambient temperature (storage/transport)
-40 °C ... 85 °C (non-condensing)
Case temperature
max. 85 °C (Operation)
Permissible humidity (operation)
30 % ... 95 % (non-condensing)
Permissible humidity (storage/transport)
30 % ... 95 % (non-condensing)
Vibration (operation)
in acc. with IEC 60068-2-6: 5g, 150 Hz
Air pressure (operation)
86 kPa ... 108 kPa (1500 m above sea level)
Air pressure (storage/transport)
66 kPa ... 108 kPa (3500 m above sea level)
Standard designation
Laser equipment safety
Standards/specifications
IEC 60825

Specifications may be subject to change without notice