Product Model

FLS IB M12 DI 8 M12

In Stock
Last updated: 2025/4/19
Phoenix Contact FLS IB M12 DI 8 M12

Selling Points

  • 1High-Performance Connectivity: Features M12 connectors for secure and reliable connections in harsh industrial environments.
  • 2Versatile Input/Output: Supports 2-, 3-, and 4-conductor connections, catering to various industrial control needs.
  • 3Durable Design: Built with robust materials to withstand demanding industrial conditions.
  • 4Easy Installation: Simple setup with standard M12 connectors, reducing installation time and effort.
  • 524V DC Power Supply: Operates on a stable 24V DC power supply, ensuring consistent performance in industrial settings.
Product Details
FLS IB M12 DI 8 M12
Phoenix Contact

Technical Specifications

Detailed engineering parameters based on manufacturer documentation

ParameterValueParameterValue
Width
60 mm
Height
161 mm
Depth
44.5 mm
Drill hole spacing
151 mm
Connection method
2x M12 connectors, B-coded
Designation connection point
Copper cable
Number of positions
5
Transmission speed
500 kbps
Number of local bus devices that can be connected
0
Number of devices with parameter channel
0
ID code (dec.)
2
ID code (hex)
02
Length code (hex)
81
Length code (dec)
129
Process data channel
0 bit
Input address area
8 bit
Output address area
0 bit
Register length
8 bit
Input name
Digital inputs
Description of the input
IEC 61131-2 type 1
Number of inputs
8
Connection method
M12 connector
Connection technology
2-, 3-, 4-conductor
Input voltage
24 V DC
Input voltage range "0" signal
-30 V DC ... 5 V DC
Input voltage range "1" signal
13 V DC ... 30 V DC
Nominal input voltage U
24 V DC
Filter time
3 ms
Protective circuit
Reverse polarity protection
Product type
I/O component
Product family
Fieldline
Type
Block design
No. of channels
8
Voltage supply U
24 V DC
Power supply at U
max. 4 A
Current consumption from U
typ. 65 mA max. 100 mA
Voltage supply U
24 V DC
Power supply at U
max. 4 A
Current consumption from U
typ. 5 mA (plus sensor current) max. 700 mA
Connection method
M12 connector (A-coded)
Designation
U
Supply voltage
24 V DC
Supply voltage range
18 V DC ... 30 V DC (including ripple)
Test voltage: 24 V supply (bus logics) / FE
500 V AC, 50 Hz, 1 s
Test voltage: 24 V supply (bus logics) / Digital inputs (sensor supply / I/O)
500 V AC, 50 Hz, 1 s
Test voltage: 24 V supply (bus logics) / Incoming remote bus
500 V AC, 50 Hz, 1 s
Test voltage: 24 V supply (bus logics) / Outgoing remote bus
500 V AC, 50 Hz, 1 s
Test voltage: Digital inputs (sensor supply / I/O) / FE
500 V AC, 50 Hz, 1 s
Test voltage: Digital inputs (sensor supply / I/O) / Incoming remote bus
500 V AC, 50 Hz, 1 s
Test voltage: Digital inputs (sensor supply / I/O) / Outgoing remote bus
500 V AC, 50 Hz, 1 s
Test voltage: Incoming remote bus / FE
500 V AC, 50 Hz, 1 s
Test voltage: Incoming remote bus / Outgoing remote bus
500 V AC, 50 Hz, 1 s
Test voltage: Outgoing remote bus / FE
500 V AC, 50 Hz, 1 s
Connection method
M12 connector
Ambient temperature (operation)
-25 °C ... 60 °C
Degree of protection
IP65/IP67
Air pressure (operation)
80 kPa ... 106 kPa (up to 2000 m above sea level)
Air pressure (storage/transport)
70 kPa ... 106 kPa (up to 3000 m above sea level)
Ambient temperature (storage/transport)
-25 °C ... 85 °C
Permissible humidity (storage/transport)
95 %
Protection class
III (IEC 61140, EN 61140, VDE 0140-1)
Mounting type
Wall mounting

Specifications may be subject to change without notice