Product Model
FLS PB M12 DO 8 M12-2A

Selling Points
- 1Equipped with 8 digital outputs, each capable of handling 2 A.
- 2Utilizes fast connection technology for efficient and reliable connections.
- 3Protected against short circuits and overloads with a 24 V DC supply.
- 4Supports various power supply configurations for adaptability in different applications.
- 5Designed for wall mounting with IP65/67 protection, suitable for harsh industrial environments.
Technical Specifications
Detailed engineering parameters based on manufacturer documentation
Parameter | Value | Parameter | Value |
---|---|---|---|
Width | 60 mm | Height | 178 mm |
Depth | 49.3 mm | Drill hole spacing | 168 mm |
Connection method | 2x M12 connectors, B-coded | Designation connection point | Copper cable |
Number of positions | 5 | Transmission speed | 9.6 kbps ... 12 Mbps (Automatic baud rate detection) |
Transmission physics | PROFIBUS-DP-compliant copper cable | Address area assignment | 1 ... 99, can be set |
Number of local bus devices that can be connected | 0 | Number of devices with parameter channel | 0 |
ID code (hex) | 066C | Input address area | 0 bit |
Output address area | 8 bit | Register length | 8 bit |
Output name | Digital outputs | Connection method | M12 connector |
Connection technology | 2-, 3-conductor | Number of outputs | 8 |
Protective circuit | Short-circuit protection | Output voltage | 24 V DC |
Maximum output current per channel | 2 A | Product type | I/O component |
Product family | Fieldline | Type | Block design |
No. of channels | 8 | Voltage supply U | 24 V DC |
Power supply at U | 4 A | Current consumption from U | typ. 40 mA
max. 100 mA |
Voltage supply U | 24 V DC | Power supply at U | max. 4 A |
Current consumption from U | typ. 3 mA
max. 700 mA | Voltage supply U | 24 V DC |
Power supply at U | max. 4 A | Current consumption at U | typ. 12 mA (plus actuator current)
max. 4 A |
Voltage supply U | 24 V DC | Power supply at U | max. 4 A |
Current consumption at U | typ. 12 mA (plus actuator current)
max. 4 A | Voltage supply U | 24 V DC |
Power supply at U | max. 4 A | Current consumption at U | typ. 12 mA (plus actuator current)
max. 4 A |
Voltage supply U | 24 V DC | Power supply at U | max. 4 A |
Current consumption at U | typ. 12 mA (plus actuator current)
max. 4 A | Connection method | M12 connector (A-coded) |
Designation | U | Supply voltage | 24 V DC |
Supply voltage range | 18 V DC ... 30 V DC (including ripple) | Test voltage: 24 V supply (bus logics) / FE | 500 V AC, 50 Hz, 1 min |
Test voltage: 24 V supply (bus logics) / Digital outputs (actuator supply) | 500 V AC, 50 Hz, 1 min | Test voltage: Bus connection / FE | 500 V AC, 50 Hz, 1 min |
Test voltage: Bus connection / Digital outputs (actuator supply) | 500 V AC, 50 Hz, 1 min | Test voltage: FE / Digital outputs (actuator supply) | 500 V AC, 50 Hz, 1 min |
Connection method | M12 connector | Ambient temperature (operation) | -25 °C ... 60 °C |
Degree of protection | IP65/IP67 | Air pressure (operation) | 80 kPa ... 106 kPa (up to 2000 m above sea level) |
Air pressure (storage/transport) | 70 kPa ... 106 kPa (up to 3000 m above sea level) | Ambient temperature (storage/transport) | -25 °C ... 85 °C |
Permissible humidity (storage/transport) | 95 % | Protection class | III (IEC 61140, EN 61140, VDE 0140-1) |
Mounting type | Wall mounting |
Specifications may be subject to change without notice