Product Model
FL SWITCH 2414-2SFX PN

Selling Points
- 1Durable Construction: Made from stainless steel 1.4301, ensuring long-lasting performance in harsh conditions.
- 2Easy Installation: Features DIN rail mounting for streamlined setup in control panels.
- 3High-Speed Connectivity: Supports transmission speeds of up to 100 Mbps (full duplex) and up to 40 km with SFP modules.
- 4Advanced Management: Includes web-based management, SNMP, and RSTP for efficient network configuration and monitoring.
- 5Robust Security: Offers port security with MAC-based and RADIUS (IEEE 802.1X) authentication for secure network expansion.
Technical Specifications
Detailed engineering parameters based on manufacturer documentation
Parameter | Value | Parameter | Value |
---|---|---|---|
Width | 214 mm | Height | 113 mm |
Depth | 67 mm | General | Support by phone or on-site (fee is charged) |
Note on application | Only for industrial use | Material base plate | Die-cast aluminum, corrosion-resistant |
Housing material | Stainless steel 1.4301 | Mounting type | DIN rail mounting |
Connection method | RJ45 | Note on the connection method | Auto negotiation and autocrossing |
Transmission speed | 10/100 Mbps | Transmission physics | Copper |
Transmission length | 100 m (per segment) | Signal LEDs | Data receive, link status |
No. of channels | 14 (RJ45 ports) | Number of interfaces | 2 |
Connection method | SFP | Transmission speed | 100 Mbps (full duplex) |
Transmission physics | Depending on the SFP module | Transmission length | up to 40 km (depending on the SFP module used) |
Signal LEDs | Data receive, link status | No. of channels | 2 (SFP ports) |
Product type | Switch | Product family | Managed Switch 2000 |
Type | Block design | MTTF | 238.46 Years (SN 29500 standard, temperature 25°C, operating cycle 21%)
137.07 Years (SN 29500 standard, temperature 40°C, operating cycle 34.25%)
21.04 Years (SN 29500 standard, temperature 70°C, operating cycle 100%) |
Special properties | Extended temperature range
PROFINET mode preset, PROFINET status LEDs
Development process certified in accordance with IEC 62443-4-1
Compatible with IEC 62443-4-2 | Signal delay | ≥ 6.5 µs (Store and Forward mode, 10/100 Mbps, depending on the frame size) |
Article revision | 03 | Protection class | III (VDE 0106) |
Degree of pollution | 2 | Diagnostic functions | RMON History
LLDP (Link Layer Discovery Protocol)
SNMP-Traps
N:1-Portmirroring
ACD (Address Conflict Detection)
SysLog
CRC-Surveillance |
Basic functions | Store-and-forward switch, complies with IEEE 802.3 | Signal contact control voltage | typ. 24 V DC |
PROFINET conformance class | Conformance-Class B | PROFINET device function | PROFINET device
Fast Startup |
Filter functions | Quality of Service (8 priority classes)
Class of Service
DiffServ/DSCP
Port-Priorisierung
VLAN (up to 32 VLANs)
IGMP Snooping/Querier (v1/v2)
Auto-Query-Port
Extended Multicast Filtering | IP parameterization | DHCP client
DHCP Option 82 (Relay Agent)
DHCP server (pool-based, port-based)
BootP
DCP (Discovery and Configuration Protocol) |
MAC address table | 8k | Management | Web-based management (HTTP/HTTPS)
Role-based user management (LDAP, RADIUS)
SNMPv1/v2/v3
Command Line Interface (Telnet, SSH) |
Redundancy | MRP (Media Redundancy Protocol)
RSTP (Rapid Spanning Tree Protocol)
FRD (Fast Ring Detection)
Large Tree Support
LACP (Link Aggregation Control Protocol)
PROFINET S2 system redundancy | Status and diagnostic indicators | LEDs: US1, US2 (power supply), Fail (alarm contact), 2 LEDs per Ethernet port (link/activity and speed), PROFINET status LEDs (BF, SF) |
Additional functions | Transmission of MMS and GOOSE (IEC 61850-8-1)
Transmission of Modbus/TCP | Time synchronization | SNTP (Simple Network Time Protocol) |
Port security | MAC-based, RADIUS (IEEE 802.1X), MAC Authentication Bypass | Basic functions | Store-and-forward switch, complies with IEEE 802.3 |
Local diagnostics | US1/2 Supply voltage US1, US2 Green LED
FAIL Div. LED red
LNK/ACT Link status Green LED
SPD Data transmission speed Green LED
BF Bus errors LED red
SF Group error LED red | Maximum power dissipation for nominal condition | 8.26 W (U |
Test section | 24 V supply / functional ground 500 V DC 1 min
Ethernet interface/all other potentials 2.25 kV DC 1 min | Transmission medium | Copper
FO |
Supply voltage (DC) | 24 V DC (redundant) | Supply voltage range | 19.2 V DC ... 32 V DC |
Power supply connection | Via COMBICON, max. conductor cross section 2.5 mm² | Residual ripple | 3.6 V |
Max. current consumption | 440 mA (U | Typical current consumption | 310 mA (at U |
Signal contact control voltage | typ. 24 V DC | Connection method | Push-in spring connection |
Note on the connection method | Use only copper connecting cables providing the permitted temperature range (-40 °C ... 75 °C). | Conductor cross section, rigid | 0.2 mm² ... 1.5 mm² |
Conductor cross section, flexible | 0.2 mm² ... 2.5 mm² | Conductor cross section AWG | 24 ... 16 |
Stripping length | 10 mm | Degree of protection | IP20 |
Ambient temperature (operation) | -40 °C ... 70 °C | Ambient temperature (storage/transport) | -40 °C ... 85 °C |
Permissible humidity (operation) | 10 % ... 95 % (non-condensing) | Permissible humidity (storage/transport) | 10 % ... 95 % (non-condensing) |
Shock (operation) | 30g (EN 60068-2-27) | Vibration (operation) | in acc. with IEC 60068-2-6: 5g, 150 Hz |
Air pressure (operation) | 79 kPa ... 108 kPa up to 2000 m above mean sea level (Without derating) | Air pressure (storage/transport) | 79 kPa ... 108 kPa up to 2000 m above mean sea level (Without derating) |
Free from substances that could impair the application of coating | Yes | Identification | cULus |
Identification | ISA S71.04.2013 G3 Harsh Group A | Temperature | B |
Humidity | B | Vibration | A |
EMC | B | Enclosure | Required protection according to the Rules shall be provided upon installation on board |
Electromagnetic compatibility | Conformance with EMC Directive 2014/30/EU | Conformance with EMC directives | EN 61000-6-2 EN 61000-4-2 (ESD) Criterion B
EN 61000-6-2 EN 61000-4-3 (electromagnetic fields) Criterion A
EN 61000-6-2 EN 61000-4-4 (EFT burst) Criterion A
EN 61000-6-2 EN 61000-4-5 (surge) Criterion A
EN 61000-6-2 EN 61000-4-6 (line noise immunity) Criterion A
EN 61000-6-2 EN 61000-6-4 (interference) Class A
EN 61000-6-2 EN 61000-6-4 (conducted interference) Class A |
Noise immunity | EN 61000-6-2 | Noise emission | EN 61000-6-4 |
Basic functions | Store-and-forward switch, complies with IEEE 802.3 | Status display | LEDs: US1, US2 (power supply), Fail (alarm contact), 2 LEDs per Ethernet port (link/activity and speed), PROFINET status LEDs (BF, SF) |
Specifications may be subject to change without notice