Product Model

FL SWITCH EP6412-4GSFP-MV

In Stock
Last updated: 2025/4/19
Phoenix Contact FL SWITCH EP6412-4GSFP-MV

Selling Points

  • 1Ensures long-lasting performance in demanding environments.
  • 2Supports standard DIN rail mounting for streamlined setup in control panels.
  • 3Reliable screw connection provides secure and stable connectivity.
  • 4Transmits at 100/1000 Mbps (full duplex) for efficient data communication.
  • 5Supports up to 100 m (per segment) transmission length, ideal for various industrial settings.
Product Details
FL SWITCH EP6412-4GSFP-MV
Phoenix Contact

Technical Specifications

Detailed engineering parameters based on manufacturer documentation

ParameterValueParameterValue
Width
82.7 mm
Height
188.39 mm
Depth
197.12 mm
Note on application
Only for industrial use
Housing material
Metal
Mounting type
DIN rail
Mounting type
DIN rail mounting
Connection method
RJ45
Note on the connection method
Auto negotiation and autocrossing
Transmission speed
10/100/1000 Mbps
Transmission physics
Copper
Transmission length
100 m (per segment)
Connection method
SFP
Transmission speed
100/1000 Mbps (full duplex)
Transmission physics
Depending on the SFP module
Output name
Alarm relay output: 24 V DC, 1 A maximum
Product type
Switch
Product family
Managed Switch EP6000
Overvoltage category
II
Degree of pollution
2
Signal contact control voltage
24 V DC
Signal contact control current
1 A
MAC address table
16k
Status and diagnostic indicators
LEDs: POWER, ERROR, Link status
Local diagnostics
Power Supply voltage Green LED Error Alarm signal LED red
Maximum power dissipation for nominal condition
max. 50 W
Transmission medium
Copper depending on the SFP module used
Supply voltage (DC)
48 V DC (Redundant DC power supplies are load sharing)
Supply voltage range
36 V DC ... 72 V DC
Signal contact control voltage
24 V DC
Signal contact control current
1 A
Connection method
Screw connection
Degree of protection
IP20
Ambient temperature (operation)
-40 °C ... 85 °C (Type tested to 85 °C for 16 hours)
Ambient temperature (storage/transport)
-40 °C ... 85 °C
Permissible humidity (operation)
5 % ... 95 % (non-condensing)
Permissible humidity (storage/transport)
10 % ... 95 % (non-condensing)
Standard designation
Ambient conditions
Standards/specifications
IEC 61850-3 IEEE 1613
Conformance
CE-compliant
Noise immunity
IEC 61850-3, IEEE 1613, EN 61000-6-2: 2005
Status display
LEDs: POWER, ERROR, Link status

Specifications may be subject to change without notice